Objective: To evaluate the time and number of laser beam passes required to make full-thickness skin incisions and extent of laser-induced tissue artifacts following use of a CO laser at various settings.

Sample: 24 skin specimens from six 5-month-old porcine carcasses.

Procedures: 4 full-thickness skin specimens were harvested from the flank regions of each carcass within 30 minutes after euthanasia and randomly assigned to 4 treatment groups. Three 5-cm-long incisions were made in each specimen with a CO laser (beam diameter, 0.4 mm) set to deliver a continuous wave of energy alone (groups 1 and 2) or in superpulse mode (groups 3 and 4) at 10 (groups 1 and 3) or 20 (groups 2 and 4) W of power. The time and number of passes required to achieve a full-thickness incision were recorded, and extent of laser-induced tissue artifact (as determined by histologic evaluation) was compared among the 4 groups.

Results: Mean time required to make a full-thickness skin incision for groups 2 and 4 (power, 20 W) was significantly less than that for groups 1 and 3 (power, 10 W). Mean number of passes was lowest for group 2 (continuous wave at 20 W). Extent of laser-induced tissue artifact was greatest for group 4 (superpulse mode at 20 W).

Conclusions And Clinical Relevance: Results provided preliminary information regarding use of CO lasers to make skin incisions in veterinary patients. In vivo studies are necessary to evaluate the effect of various CO laser settings on tissue healing and patient outcome.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.81.6.514DOI Listing

Publication Analysis

Top Keywords

full-thickness skin
16
laser-induced tissue
16
time number
12
laser beam
12
passes required
12
required full-thickness
12
tissue artifact
12
extent laser-induced
12
groups power
12
laser settings
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!