The Woven EndoBridge Device (WEB) is efficient and safe in the treatment of wide-neck bifurcation intracranial aneurysms. A crucial step in operative planning is establishing the appropriate dimension of the device, and there are limitations to the therapeutic solutions provided by WEBs. We describe a case of a right middle cerebral artery bifurcation wide-neck aneurysm treated with WEB. After the initial deployment of a WEB proven oversized, we substituted it with a smaller one that presented immediate post-detachment intra-aneurysmal tilt probably resulting from undersizing. The 24-h angiographic control identified a partial displacement of the device in the superior middle cerebral artery branch. We describe rescue techniques with review of the literature and our treatment strategy, including effort to reposition the device followed by stent deployment. The treatment was electively completed by the coil-through technique. The post-detachment WEB tilt should be considered an unstable position and treated either by removal of the device or with adjunctive implants. Each WEB size adapts to a range of aneurysmal height and width. This range is not always the same for each specific WEB dimension, based on the table provided by the manufacturer. This eventually predisposes to a different behavior of different WEB sizes regarding the modification of the device's height in relation to the modification of the diameter after deployment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7446579PMC
http://dx.doi.org/10.1177/1591019920926334DOI Listing

Publication Analysis

Top Keywords

woven endobridge
8
endobridge device
8
rescue techniques
8
techniques review
8
review literature
8
middle cerebral
8
cerebral artery
8
web
7
device
6
device post-detachment
4

Similar Publications

The Woven EndoBridge (WEB) device has become a prominent treatment for wide-neck bifurcation intracranial aneurysms since its FDA approval in 2018. However, the impact of anticoagulant therapy on its efficacy and patient outcomes remains underexplored. This study aims to evaluate the effects of postoperative anticoagulant use on aneurysm occlusion, retreatment rates, and functional outcomes following WEB device implantation.

View Article and Find Full Text PDF

Purpose: Various angiographic assessment scales have been used to report the results of endovascular treatment with the WEB device. We aimed to review the use and reliability of these scales.

Methods: We systematically reviewed studies reporting angiographic outcomes of WEB-treated aneurysms from January 2010 to May 2023.

View Article and Find Full Text PDF

Background And Objectives: The Woven EndoBridge (WEB) device is a breakthrough in brain aneurysm treatment, widely used for intracranial wide neck and complex aneurysms, especially at bifurcations. Although effective, aneurysm recurrence can occur post-treatment and the impact of clipping angle on the WEB mesh remains unclear. In this study, using a human placenta-based ex-vivo aneurysm model, we simulated the application of aneurysm clipping on WEB-treated aneurysms to elucidate the technical aspects and nuances, particularly the influence of the angle of clip application on WEB collapse.

View Article and Find Full Text PDF

Purpose: The safety and efficacy of Woven EndoBridge (WEB) treatment has been proven. However, only a few standard techniques for safe and versatile WEB deployment have been described in the literature. In this study, we introduce the "make a flower bud and push at neck" technique to achieve safety and versatility during WEB treatment, referred to simply as the "flower bud" technique.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!