Background/aims: Few studies have objectively examined the quality of eye care in China. We assessed refractive care using the incognito standardised patient (SP) approach, a gold standard for evaluating clinical practice.

Methods: A total of 52 SPs were trained to provide standardised responses during eye examinations, and underwent automated and non-cycloplegic, subjective refraction by a senior ophthalmologist from Zhongshan Ophthalmologic Center, a national-level clinical and research centre. SPs subsequently received subjective refraction and eye exams at a randomly selected sample of 40 public hospitals and 93 private optical shops in Shaanxi, Northwestern China. Difference between expert and local refraction in the better-seeing eye was calculated by the vector diopteric method, and completeness of exams assessed against national standards. SP and provider demographic information and provider clinical experience were recorded.

Results: SPs (n=52, mean (range) age, 25.7 (22-31) years, 28.8% male) underwent 133 eye exams (mean total duration 15.0±11.7 min) by 133 local refractionists (24-60 years, 30.3% male). Only 93 (69.9%), 121 (91.0%) and 104 (78.2%) of local refractionists assessed vision, automated and subjective refraction, respectively. The median inaccuracy was -0.25 diopters (D), while 25.6% of results differed by an absolute value of ≥1.0 D and 6.0% by ≥2.0 D. Predictors of inaccurate refraction included spectacle power <-6.0 D (OR=2.66; 95% CI, 1.27 to 5.56), service at a public (vs private) hospital (OR=2.01; 95% CI, 1.11 to 3.63) and provider male sex (OR=2.03; 95% CI, 1.11 to 3.69).

Conclusion: Inaccurate refractions are common in Northwestern China, particularly in public facilities. Important assessments, including subjective refraction, are frequently omitted.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjophthalmol-2019-315103DOI Listing

Publication Analysis

Top Keywords

subjective refraction
12
incognito standardised
8
quality eye
8
eye care
8
care china
8
eye exams
8
local refractionists
8
eye
6
refraction
5
standardised patients
4

Similar Publications

Tooth shade selection is a fundamental factor in the success of dental restorations, and visual impairment may adversely affect this process. The aim of this cross-sectional clinical study was to determine whether visual impairment influences shade selection using two methods: spectrophotometry and shade guides. : The sample consisted of 2796 maxillary and mandibular teeth, and shade selection was measured subjectively with a shade guide (VITA Classic, VITA Zahnfabrik) and objectively with a spectrophotometer (VITA Easyshade V, VITA Zahnfabrik, Bad Säckingen, Germany).

View Article and Find Full Text PDF

Significance: Epidemiological information about the epiretinal membrane is important for better clinical management and understanding of the nature and burden of this disease. There are some gaps in our understanding of the epidemiology of epiretinal membranes, particularly in Africa and the Middle East.

Purpose: This study aimed to determine the prevalence and risk factors of epiretinal membrane using spectral-domain optical coherence tomography (OCT) in an Iranian elderly population.

View Article and Find Full Text PDF

Purpose: To compare the clinical outcomes, surgical workflow, and patient satisfaction following small incision lenticule extraction (SMILE) performed with the VisuMax 800 in one eye and the VisuMax 500 in the contralateral eye (both Carl Zeiss Meditec).

Methods: This was a prospective, single-site clinical study of patients undergoing SMILE for myopia and myopic astigmatism between February 2022 and August 2023. Each patient underwent bilateral treatment using the VisuMax 800 (VM800 group) in one eye and the VisuMax 500 (VM500 group) in the contralateral eye.

View Article and Find Full Text PDF

Background: Contrast sensitivity is an important measure of vision quality. Risk of falling injury is strongly associated with poor contrast sensitivity compared with poor near- and distance visual acuity. Since good visual acuity is not necessarily associated with good visual performance in the "real world" it is important to consider contrast sensitivity when prescribing corrective lenses.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated the prevalence and factors associated with anisometropia (a condition where each eye has a different prescription) among 134,603 refractive surgery candidates in Germany from 2010 to 2020.
  • Results indicated that 17.9% of the population had anisometropia, with variables like age, sex, and spherical/cylindrical ametropia significantly affecting its occurrence—different impacts were noted in hyperopes (farsighted individuals) versus myopes (nearsighted individuals).
  • The findings reveal that increased cylindrical ametropia reduced anisometropia in hyperopes, while in myopes, it correlates positively with age and spherical power, showcasing the complexity
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!