Background: The double lumen endotracheal tube (DLT) is the most widely-used device for single lung ventilation in current thoracic anesthesia practice. In recent years, the routine application of the videolaryngoscope for single lumen endotracheal intubation has increased; nevertheless there are few studies of the use of the videolaryngoscope for DLT. We wondered whether there were benefits to using the videolaryngoscope for DLT placement in patients with predicted normal airways. Therefore, this study was designed to compare the performances of the GlideScope®, the C-MAC®(D) videolaryngoscope and the Macintosh laryngoscope in DLT intubation.

Methods: This was a randomized, controlled, prospective study. We randomly allocated 90 adult patients with predicted normal airways into three groups. All patients underwent routine anesthesia using different laryngoscopes according to group allocation. We compared DLT insertion times, first-pass success rates, numerical rating scales (NRS) of DLT delivery and DLT insertion, Cormack-Lehane degrees (C/L), hemodynamic changes and incidences of intubation complications. All outcomes were analyzed using SPSS13.0.

Results: Compared with the GlideScope, the Macintosh gave shorter times for DLT insertion (median: 96 (IQR: 51 [min-max: 62-376] s vs 73 (26 [48-419] s, p = 0.003); however, there was no difference between the Macintosh and C-MAC(D) (p = 0.610). The Macintosh had a significantly higher successful first attempt rate than did the GlideScope or C-MAC(D) (p = 0.001, p = 0.028, respectively). NRS of DLT delivery and insertion were significantly lower in the Macintosh than in the others (p < 0.001). However, the C/L degree in the Macintosh was significantly higher than in the others (p < 0.001). The incidences of oral bleeding, hoarseness, sore throat and dental trauma were low in all groups (p > 0.05). There were no significant differences in DLT misplacement, fiberoptic time or hemodynamic changes among the groups.

Conclusions: Compared with the Macintosh laryngoscope, the GlideScope® and C-MAC®(D) videolaryngoscopes may not be recommended as the first choice for routine DLT intubation in patients with predicted normal airways.

Trial Registration: The study was prospectively registered at the Chinese Clinical Trial Registry (no. ChiCTR1900025718); principal investigator: Z.L.H.; date of registration: September 6, 2019.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7238523PMC
http://dx.doi.org/10.1186/s12871-020-01012-yDOI Listing

Publication Analysis

Top Keywords

lumen endotracheal
12
patients predicted
12
predicted normal
12
normal airways
12
dlt insertion
12
dlt
9
c-mac®d videolaryngoscope
8
macintosh laryngoscope
8
double lumen
8
endotracheal intubation
8

Similar Publications

Abstarct: BACKGROUND: The optimal positioned double-lumen endotracheal tubes (DLT) is crucial in thoracic surgery requiring lung isolation. This study aims to compare the accuracy and complication rates of DLT placement using videolaryngoscopy (VL) versus conventional direct laryngoscopy (DL).

Methods: This retrospective single-center study included 89 patients who underwent thoracic surgery with DLT placement between July 2023 and May 2024.

View Article and Find Full Text PDF

Objectives: Pressurized IntraThoracic Aerosol Chemotherapy (PITAC) has been suggested as a new therapy for patients with malignant pleural effusion (MPE) and/or pleural metastasis (PLM). The patients have a poor prognosis with a median survival of 3 to 12 months. We present feasibility, patient safety, and cytological/histological response assessment in PITAC-treated patients with MPE and/or PLM.

View Article and Find Full Text PDF

Background: Non-invasive ventilation combined with pulmonary surfactant (PS) therapy is recognised as a method for treating neonatal respiratory distress syndrome (NRDS). Among the administration, methods of PS, INtubation-SURfactant-Extubation (InSurE) and less invasive surfactant administration (LISA) have been widely discussed.LISA technique prevents patients from exposure to invasive positive pressure ventilation (PPV), thus improving the long-term outcomes of the respiratory system, but it faces challenges in resource-limited areas due to complexity and cost.

View Article and Find Full Text PDF

Background: Common causes of air leakage around an endotracheal tube include insufficient endotracheal tube cuff inflation and damage to the cuff, while damage to the pilot balloon or pilot balloon tubing is relatively rare.

Case Presentation: A 74-year-old female with vertebral osteomyelitis was scheduled for an extreme lateral interbody fusion followed posterior fixation. A fiber-optic light was utilized as part of the surgical illuminator.

View Article and Find Full Text PDF

Objective: To study the clinical effectiveness of visual laryngoscopy combined with fiberoptic bronchoscopy-guided double-lumen endotracheal tube intubation in thoracic surgery patients with predicted difficult airways in thoracic surgery airways.

Methods: We randomly divided 162 patients with predicted difficult airways who required double-lumen tracheal intubation for thoracic surgery and randomly divided them into the video laryngoscopy group (Group VL, n = 54),fiberoptic bronchoscopy group (Group F, n = 54), and video laryngoscopy combined with fiberoptic bronchoscopy group (Group FVL, n = 54) according to the randomized number table method. Then, the success rate of the first intubation, the duration of intubation, the duration of positioning, the degree of exposure of the vocal cords (Cormack-Lehane grade), and the adverse reactions during intubation were recorded and analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!