The creation of intracranial stereotactic trajectories, from entry point to target point, is still mostly done manually by the neurosurgeon. The development of automated stereotactic planning tools has been described in the literature. This systematic review aims to assess the effectiveness of stereotactic planning procedure automation and develop tools for patients undergoing neurosurgical stereotactic procedures. PubMed/MEDLINE, EMBASE, Google Scholar, CINAHL, PsycINFO, and Cochrane Register of Controlled Trials databases were searched from inception to September 1, 2019, at the exception of Google Scholar (from 1 January 2010 to September 1, 2019) in French and English. Eligible studies included all studies proposing automated stereotactic planning. A total of 1543 studies were screened. Forty-two studies were included in the systematic review, including 18 (42.9%) conference papers. The surgical procedures planned automatically were mainly deep brain stimulation (n = 14, 33.3%), stereoelectroencephalography (n = 12, 28.6%), and not specified (n = 10, 23.8%). The most frequently used surgical constraints to plan the trajectory were blood vessels (n = 32, 76.2%), cerebral sulci (n = 27, 64.3%), and cerebral ventricles (n = 23, 54.8%). The distance from blood vessels ranged from 1.96 to 4.78 mm for manual trajectories and from 2.47 to 7.0 mm for automated trajectories. At least one neurosurgeon was involved in 36 studies (85.7%). The automated stereotactic trajectory was preferred in 75.4% of the studied cases (range 30-92.9). Only 3 (7.1%) studies were multicentric. No study reported prospective use of the planning software. Stereotactic planning automation is a promising tool to provide valuable stereotactic trajectories for clinical applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10143-020-01315-1 | DOI Listing |
Curr Oncol
December 2024
Specialty Hospital Radiochirurgia Zagreb, 10431 Sveta Nedelja, Croatia.
We present a patient treated with personalized ultra-fractionated stereotactic adaptive radiotherapy (PULSAR) for non-small cell lung cancer (NSCLC) using the adaptive Varian Ethos™ system equipped with the novel HyperSight imaging platform. Three pulses of 12 Gy were separated by a pause of four weeks during which the tumor was given enough time to respond to treatment. Only initial planning computed tomography (CT) was acquired on a CT simulator (Siemens Somatom Definition Edge), whereas other pulses were adapted using online cone beam computed tomography (CBCT) images (iCBCT Acuros reconstruction) acquired while the patient was lying on the treatment couch and delivered immediately.
View Article and Find Full Text PDFFront Oncol
December 2024
Department of Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, United States.
Purpose: The purpose of this study was to investigate the dosiomics features of the interplay between CT density and dose distribution in lung SBRT plans, and to develop a model to predict treatment failure following lung SBRT treatment.
Methods: A retrospective study was conducted involving 179 lung cancer patients treated with SBRT at the University of Nebraska Medical Center (UNMC) between October 2007 and June 2022. Features from the CT image, Biological Effective Dose (BED) and five interaction matrices between CT and BED were extracted using radiomics mathematics.
J Radiat Res
December 2024
Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi, 466-8550, Japan.
Dynamic WaveArc (DWA) is a technique used for continuous, non-coplanar volumetric-modulated arc therapy on the Vero4DRT platform. This study aimed to evaluate the application of single-isocenter DWA (SI-DWA) for treating multiple brain metastases by comparing dose distribution and irradiation time with multi-isocenter DWA (MI-DWA) through retrospective treatment planning. Treatment plans were developed for SI-DWA and MI-DWA in 14 cases with 3-5 brain metastases.
View Article and Find Full Text PDFJ Contemp Brachytherapy
October 2024
Radiation Oncology, Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum University of Bologna, Bologna, Italy.
Purpose: This systematic review aimed to assess the feasibility, safety, and efficacy of using modern external beam radiotherapy (EBRT) techniques, such as intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), and stereotactic body radiotherapy (SBRT) as alternative approaches to brachytherapy (BRT) in adjuvant treatment of endometrial cancer (EC).
Material And Methods: A systematic review was conducted following PRISMA guidelines. The research question was framed using the PICO method, focusing on patients with EC [P] and comparing modern EBRT techniques (IMRT, VMAT, SBRT) [I] vs.
Phys Imaging Radiat Oncol
October 2024
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States.
Purpose: Multiparametric magnetic resonance imaging (MRI) is known to provide predictors for malignancy and treatment outcome. The inclusion of these datasets in workflows for online adaptive planning remains under investigation. We demonstrate the feasibility of longitudinal relaxometry in online MR-guided adaptive stereotactic body radiotherapy (SBRT) to the prostate and dominant intra-prostatic lesion (DIL).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!