Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Respiratory activity is an essential parameter to monitor healthy and disordered sleep, and unobtrusive measurement methods have important clinical applications in diagnostics of sleep-related breathing disorders. We propose a respiratory activity surrogate extracted from wrist-worn reflective photoplethysmography validated on a heterogeneous dataset of 389 sleep recordings.
Approach: The surrogate was extracted by interpolating the amplitude of the PPG pulses after evaluation of pulse morphological quality. Subsequent multistep post-processing was applied to remove parts of the surrogate with low quality and high motion levels. In addition to standard respiration rate performance, we evaluated the similarity between surrogate respiratory activity and reference inductance plethysmography of the thorax, using Spearman's correlations and spectral coherence, and assessed the influence of PPG signal quality, motion levels, sleep stages and obstructive sleep apnea.
Main Results: Prior to post-processing, the surrogate already had a strong similarity with the reference (correlation = 0.54, coherence = 0.81), and reached respiration rate estimation performance in line with the literature (estimation error = 0.76± 2.11 breaths/min). Detrimental effects of low PPG quality, high motion levels and sleep-dependent physiological phenomena were significantly mitigated by the proposed post-processing steps (correlation = 0.62, coherence = 0.88, estimation error = 0.53± 1.85 breaths/min).
Significance: Wrist-worn PPG can be used to extract respiratory activity, thus allowing respiration monitoring in real-world sleep medicine applications using (consumer) wearable devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6579/ab9481 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!