A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Real-world experience of the role of 18F FDG PET-computed tomography in chronic spinal implant infection. | LitMetric

Objectives: The presence of postinstrumentation back pain in patients after undergoing spinal surgery is a well established phenomenon. So too is the presence of infection, both overt and subclinical which can be a source of pain. The accurate assessment of infection in patients with spinal implants in situ and no overt radiological or biochemical abnormalities frequently presents a diagnostic challenge. We present our experience spanning 5 years of using 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography (18F FDG PET)-computed tomography (CT) scans to aid the diagnostic process in treating presumed low-grade chronic implant infection.

Methods: We undertook a retrospective analysis of all patients with spinal implants in place who were referred for 18F FDG PET-CT imaging over a 5-year period. All available images, case notes and laboratory results were reviewed.

Results: Data pertaining to 49 patients were analysed, with infection diagnosed on 18F FDG PET-CT in 24 (45%) of those sent for scanning. Fifteen patients in the cohort underwent revision surgery, and 11 of whom had been diagnosed as infected on PET-CT. Confirmation of infection with positive microbiological sampling occurred in 8/11 giving a positive predictive value of 0.72 in our series.

Conclusion: We present a real-world experience of using 18F FDG PET-CT as a diagnostic tool in the evaluation of patients with chronic pain after undergoing spinal implantation. We have found PET-CT to be a promising modality and would recommend multicentre collaboration to ensure reproducibility across more centres.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0000000000001211DOI Listing

Publication Analysis

Top Keywords

18f fdg
20
fdg pet-ct
12
real-world experience
8
fdg pet-computed
8
pet-computed tomography
8
undergoing spinal
8
patients spinal
8
spinal implants
8
patients
6
18f
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!