Objective: This study aimed to determine which colour contrast sensitivity differences exist in early to advanced age-related macular degeneration (AMD) and examine the potential utility of the King-Devick Variable Color Contrast Sensitivity Chart in detecting AMD severity.

Methods And Analysis: A total of 85 participants (144 total eyes) were recruited from multiple clinical practices and enrolled in the study. The control group consisted of 57 healthy eyes. The non-exudative AMD (NE-AMD) group consisted of 45 eyes. The exudative AMD (E-AMD) group consisted of 42 eyes. In a single study visit, monocular best-corrected visual acuity (BCVA) at 40 cm with 100% black contrast was determined for each eye. Using the BCVA line, the number of letters correctly identified (out of 10) was recorded for various colour presentations (red, green, blue and yellow) and at decreasing contrast levels (100%, 75%, 50% and 25%).

Results: Our results show worse visual performance under various colour contrast settings in E-AMD patients compared with healthy controls and NE-AMD. Colour contrast performance using blue and yellow differentiated more advanced stages of disease in E-AMD from earlier NE-AMD disease. Blue and black colour contrast performance more accurately identified the E-AMD group from healthy controls and the NE-AMD group.

Conclusion: The findings of this study demonstrate that colour contrast, particularly with black, blue and yellow, is impaired in E-AMD suggesting the potential for colour contrast measures to serve as an adjunctive clinical tool in identifying subtle altered visual function as well as the potential for detecting disease severity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7228553PMC
http://dx.doi.org/10.1136/bmjophth-2020-000451DOI Listing

Publication Analysis

Top Keywords

colour contrast
24
contrast sensitivity
12
group consisted
12
blue yellow
12
contrast
10
king-devick variable
8
variable color
8
color contrast
8
sensitivity chart
8
age-related macular
8

Similar Publications

Dental fluorosis (DF) is a condition affecting tooth enamel that occurs during the development of permanent teeth, resulting from excessive fluoride consumption. Based on the severity, the tooth surface exhibits discoloration or structural anomalies. The range of colors varies from mild discoloration to severe dark brown lesions.

View Article and Find Full Text PDF

Polarization-sensitive optical coherence tomography (PS-OCT) measures the polarization state of backscattered light from tissues and provides valuable insights into the birefringence properties of biological tissues. Contrastive unpaired translation (CUT) was used in this study to generate a synthetic PS-OCT image from a single OCT image. The challenges related to extensive data requirements relying on labeled datasets using only pixel-wise correlations that make it difficult to efficiently regenerate the periodic patterns observed in PS-OCT images were addressed.

View Article and Find Full Text PDF

In the UK Oral and Maxillofacial Surgery (OMFS) and Oral Surgery (OS) are distinct specialties governed respectively by the General Medical Council (GMC) and General Dental Council (GDC) respectively. There has always been overlap of training and care between both specialties. The OMFS curriculum was updated in 2021 and the Oral Surgery Curriculum in 2023.

View Article and Find Full Text PDF

Bullet characterization using Photon-Counting detector CT: A phantom study with intact bullets.

Eur J Radiol

December 2024

Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, the Netherlands; Mental Health and Sciences (MHeNs) Research Institute, Maastricht University, PO Box 616, 6200 MD Maastricht, the Netherlands.

Objectives: Photon-counting detector CT (PCD-CT) is expected to substantially improve and expand CT-imaging applicability due to its intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise, and improved image contrast. The current study aim is to evaluate PCD-CT efficacy in characterizing bullets based on their dimensions, shape, and material composition.

Materials And Methods: This is an observational phantom study examining 11 unfired, intact bullets of various common calibers, placed in ballistic gelatin.

View Article and Find Full Text PDF

Analytical thin layer chromatography (TLC) is a simple yet powerful chromatographic technique that is widely used for the qualitative characterization of complex mixtures such as plant extracts. For their qualitative and visual characterisation, a large number of more or less specific colour reactions are at hand and numerous reference substances are available as well. However, the identification of extract components by colour and the comparison of retention times is not straightforward.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!