Purpose: The purpose of this study was to evaluate the effectiveness of both a resin primer containing methyl methacrylate (MMA) and a silanizing agent on bonding to indirect resin composite blocks, using two types of build-up hybrid resin composites.
Methods: SHOFU BLOCK HC (Shofu) specimens were blasted with alumina, after which one of two surface treatments was applied: CERA RESIN BOND (Shofu, the Silane group) or HC primer (Shofu, the MMA group). Resin composites made using either Solidex Hardura (SDH, Shofu) or Ceramage Duo (CMD, Shofu) were built up and micro-tensile bond strength (μTBS) values were measured after storage in water for either 24h or 6 months (n=24 per group). The fracture surfaces after μTBS measurements and the resin block/build-up resin interfaces were observed by scanning electron microscopy (SEM).
Results: The bond strength of the Silane/SDH group significantly decreased after 6 months (p<0.001), whereas in the MMA group there was no significant loss after 24h or 6 months (p=0.99). In the CMD group, the bond strength after 6 months was significantly lowered in both the Silane group (p<0.001) and the MMA group (p<0.001), but the latter still showed greater adhesion. SEM images demonstrated that the matrix resin was partially destroyed at the fracture surfaces of the MMA group and fracture surface unevenness was observed.
Conclusions: A primer containing MMA produced stronger bonding to CAD/CAM resin even after long-term aging compared to a silane treatment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpor.2019.09.004 | DOI Listing |
Background: Dental caries is one of the most common non-communicable diseases in humans. Various interventions are available for the management, of which microinvasive techniques such as infiltration, sealants, glass ionomers, are novel and convenient. The purpose of this systematic review and meta-analysis was to compare microinvasive techniques with noninvasive or invasive treatment modalities in terms of effectiveness in halting interproximal caries lesion progression radiographically assessed.
View Article and Find Full Text PDFSci Rep
January 2025
School of Materials and Metallurgy, University of Science and Technology Liaoning, Anshan, 114051, China.
In order to provide long-term anti-corrosion properties of the coatings on the substrate, a microcapsule self-healing coatings system was designed in this paper. Microcapsules were synthesized with ethyl cellulose and octadecyl amine, which were added to epoxy resin to prepare self-healing coatings. The shape of microcapsules was spherical, the average particle size of microcapsules was about 100-120 μm, and the average thickness of microcapsules was 4.
View Article and Find Full Text PDFDent Mater
January 2025
Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Preclinical Dentistry, Semmelweis University, Budapest, Hungary. Electronic address:
Objectives: This systematic review and network meta-analysis aimed to compare different PMMA (polymethyl methacrylate) complete denture base manufacturing techniques by evaluating their mechanical properties. The objective was to determine which method-compression molding, injection molding, milling, or 3D printing-offers the best performance.
Data: In vitro studies investigating mechanical properties of PMMA denture base resins.
J Prosthodont Res
January 2025
Institute of Dentistry, Department of Biomaterials Science and Turku Clinical Biomaterials Centre - TCBC, Turku, Finland.
Purpose: This study investigated the bond strength between short fiber-reinforced resin composite (SFC) and dentin following air abrasion with various types of abrasive particles.
Methods: A total of 120 human molars were prepared for a shear bond strength (SBS) test of the resin composite. The teeth were divided into 12 groups (n = 10/group) based on the air abrasion particle used.
Carbohydr Polym
March 2025
State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, 15 North Third Ring Road East, Chaoyang District, Beijing 100029, China. Electronic address:
Conductive hydrogels have emerged as excellent candidates for the design and construction of flexible wearable sensors and have attracted great attention in the field of wearable sensors. However, there are still serious challenges to integrating high stretchability, self-healing, self-adhesion, excellent sensing properties, and good biocompatibility into hydrogel wearable devices through easy and green strategies. In this paper, multifunctional conductive hydrogels (PCGB) with good biocompatibility, high tensile (1694 % strain), self-adhesive, and self-healing properties were fabricated by incorporating boric acid (BA) and glucose (Glu) simultaneously into polyacrylic acid (PAA) and chitosan (CS) polymer networks using a simple one-pot polymerization method.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!