Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Sensitive, reproducible visual function biomarkers are necessary to evaluate the efficacy of emerging treatments for Stargardt disease type 1 in clinical trials. We previously demonstrated that fixation stability may serve as a secondary outcome parameter for visual function loss. However, the test duration and protocol have an unknown effect on the assessment of fixation stability. Here, we hypothesize that separate fixation testing with a single target is different from combined fixation testing using the same target with simultaneous perimetry testing.
Design: International, multicenter, prospective, cross-sectional study.
Methods: Microperimetry data from the international, multicenter, prospective Progression of Atrophy Secondary to Stargardt Disease (ProgStar, NCT01977846) study were analyzed. Patients underwent various types of fixation testing including static testing and dynamic testing, and a duration-corrected dynamic test was generated (30sEpoch).
Results: A total of 437 eyes from 235 patients were included (mean age, 33.8 ± 15.1 years; 55.3% female). The mean 1SD-BCEA (bivariate contour ellipse area), which is the smallest ellipse encompassing 1 standard deviation of all fixation events, was smaller for the static fixation test compared to the 30sEpoch (4.5 ± 6.9 deg vs 5.3 ± 7.0 deg; P = .02) and the number of points within both the 2-degree and 4-degree circles was larger (P < .0001).
Conclusions: Our results suggest that differences in static and dynamic assessment of fixation stability are dependent not only on different test durations but also on the testing protocol of a single fixation target vs fixation target plus simultaneous perimetry testing and provide information on the conduct of fixation testing for clinical trials.