New Findings: What is the central question of this study? Splenic contractions occur in response to apnoea-induced hypoxia with and without face immersion in water. However, the splenic responses to a series of static or dynamic apnoeas with whole-body water immersion in non-divers and elite breath-hold divers are unknown. What is the main finding and its importance? Static and dynamic apnoeas were equally effective in stimulating splenic contractions across non-divers and elite breath-hold divers. These findings demonstrate that the magnitude of the splenic response is largely dictated by the degree of the hypoxemic stress encountered during voluntary apnoeic epochs.

Abstract: Splenic contractions occur in response to apnoea-induced hypoxia with and without facial water immersion. However, the splenic responses to a series of static (STA) or dynamic (DYN) apnoeas with whole-body water immersion in non-divers (NDs) and elite breath-hold divers (EBHDs) are unknown. EBHD (n = 8), ND (n = 10) and control participants (n = 8) were recruited. EBHD and ND performed a series of five maximal DYN or STA on separate occasions. Control performed a static eupnoeic (STE) protocol to control against any effects of water immersion and diurnal variation on splenic volume and haematology. Heart rate (HR) and peripheral oxygen saturation (SpO ) were monitored for 30 s after each apnoea. Pre- and post-apnoeic splenic volumes were quantified ultrasonically, and blood samples were drawn for haematology. For EBHD and ND end-apnoeic HR was higher (P < 0.001) and SpO was lower in DYN (P = 0.024) versus STA. EBHD attained lower end-apnoeic SpO during DYN and STA than NDs (P < 0.001). Splenic contractions occurred following DYN (EBHD, -47 ± 6%; ND, -37 ± 4%; P < 0.001) and STA (EBHD, -26 ± 4%; ND, -26 ± 8%; P < 0.01). DYN-associated splenic contractions were greater than STA in EBHD only (P = 0.042). Haemoglobin concentrations were higher following DYN only (EBHD, +5 ± 8g/L  , +4 ± 2%; ND, +8 ± 3 g/L , +4.9 ± 3%; P = 0.019). Haematocrit remained unchanged after each protocol. There were no between group differences in post-apnoeic splenic volume or haematology. In both groups, splenic contractions occurred in response to STA and DYN when combined with whole-body immersion. DYN apnoeas, were effective at increasing haemoglobin concentrations but not STA apnoeas. Thus, the magnitude of the splenic response relates to the hypoxemic stress encountered during apnoeic epochs.

Download full-text PDF

Source
http://dx.doi.org/10.1113/EP088404DOI Listing

Publication Analysis

Top Keywords

water immersion
16
splenic responses
12
responses series
12
static dynamic
12
dynamic apnoeas
12
apnoeas whole-body
12
splenic contractions
12
elite breath-hold
12
breath-hold divers
12
splenic
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!