The recent advancement of motion tracking technology offers better treatment tools for conditions, such as movement disorders, as the outcome of the rehabilitation could be quantitatively defined. The accurate and fast angular information output of the inertial measurement unit tracking systems enables the collection of accurate kinematic data for clinical assessment. This article presents a study of a low-cost microelectromechanical system inertial measurement unit-based tracking system in comparison with the conventional optical tracking system. The system consists of seven microelectromechanical system inertial measurement units, which could be mounted on the lower limbs of the subjects. For the feasibility test, 10 human participants were instructed to perform three different motions: walking, running, and fencing lunges when wearing specially designed sleeves. The subjects' lower body movements were tracked using our inertial measurement unit-based system and compared with the gold standard-the NDI Polaris Vega optical tracking system. The results of the angular comparison between the inertial measurement unit and the NDI Polaris Vega optical tracking system were as follows: the average cross-correlation value was 0.85, the mean difference of joint angles was 2.00°, and the standard deviation of joint angles was ± 2.65°. The developed microelectromechanical system-based tracking system provides an alternative low-cost solution to track joint movement. Moreover, it is able to operate on an Android platform and could potentially be used to assist outdoor or home-based rehabilitation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0954411920921695 | DOI Listing |
Phys Rev Lett
December 2024
The Australian National University, Department of Quantum Science and Technology, Canberra, Australian Capital Territory 2601, Australia.
We demonstrate an atom interferometer measurement protocol compatible with operation on a dynamic platform. Our method employs two open interferometers, derived from the same atomic source, with different interrogation times to eliminate initial velocity dependence while retaining precision, accuracy, and long term stability. We validate the protocol by measuring gravitational tides, achieving a precision of 4.
View Article and Find Full Text PDFComput Biol Med
January 2025
Khalifa University, Abu Dhabi, United Arab Emirates. Electronic address:
Musculoskeletal modeling based on inverse dynamics provides a cost-effective non-invasive means for calculating intersegmental joint reaction forces and moments, solely relying on kinematic data, easily obtained from smart wearables. On the other hand, the accuracy and precision of such models strongly hinge upon the selected scaling methodology tailored to subject-specific data. This study investigates the impact of upper body mass distribution on internal and external kinetics computed using a comprehensive musculoskeletal model during level walking in both normal weight and obese individuals.
View Article and Find Full Text PDFActa Bioeng Biomech
June 2024
1Department of Rehabilitation Medicine, Southern Medical University Nanfang Hospital, Guangzhou, China.
: The purpose of this study was to quantify the impact of smartphone use while sitting on the toilet on the spinal flexion angles and the time effect. : Measurements of the spinal flexion angles in the sagittal plane were made by thirty participants while they sat on the toilet for 10 min, using a smartphone in either one, both, or neither hand. The individual's forehead, cervical, thoracic and lumbar spinal areas were each fitted with five different inertial motion sensors.
View Article and Find Full Text PDFJ Acoust Soc Am
January 2025
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.
View Article and Find Full Text PDFPhysiother Theory Pract
January 2025
Faculty of Sport, University of Ljubljana, Ljubljana, Slovenia.
Background: Previous studies suggest that cervical spine position sense declines with age, while the relationship between aging and cervical spine movement control remains unknown.
Objective: To investigate the relationship between age and cervical spine movement control in asymptomatic adults.
Methods: One hundred five asymptomatic adults (21-79 years old) were included.