Background: Complications decrease after transfemoral transcatheter aortic valve implantation (TAVI), and early discharge is feasible and safe in selected populations.
Aims: To evaluate length of stay (LOS) and reasons for prolonged hospitalisation after transfemoral TAVI in unselected patients.
Methods: Patients with severe aortic stenosis, who had transfemoral TAVI with the SAPIEN 3 prosthesis using exclusively local anaesthesia, were prospectively and consecutively included at five French high-volume centres. LOS was calculated from TAVI procedure to discharge. Reasons for prolonged hospitalisation (i.e.>3 days) were evaluated.
Results: Between 2017 and 2018, 293 patients were included, with a mean age of 82.4±6.5 years and a mean logistic EuroSCORE of 13.7±9.0%. The in-hospital mortality rate was 1.4%. The median LOS was 5 (3-7) days, and varied considerably between centres (from 2 to 7 days). Sixty-four (21.8%) patients were discharged within 3 days after transfemoral TAVI. Reported reasons for prolonged hospitalisation were complications in 62.2%, loss of autonomy in 3.1%, discharge refusal in 2.2% and logistical reasons in 0.9%. In 31.6% of cases, the investigators reported no apparent reasons.
Conclusions: The results of our study suggest that LOS after transfemoral TAVI, using the SAPIEN 3 prosthesis and a minimalist approach, varies considerably between centres. In almost a third of cases, hospitalisation was prolonged without any apparent reason. Efforts should be made to educate centres to reduce LOS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.acvd.2019.11.010 | DOI Listing |
J Cardiol
January 2025
Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan.
Background: Delirium is associated with patient prognosis after transcatheter aortic valve implantation (TAVI). However, the prognostic impact of subsyndromal delirium, described as an intermediate stage between delirium and normal cognition, is uncertain. The present study aimed to investigate the prognostic impact of delirium severity in patients undergoing TAVI.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Department of Cardiology, Komaki City Hospital, 1-20 Joubushi, Komaki, Aichi 485-8520, Japan.
Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.
View Article and Find Full Text PDFJ Clin Med
December 2024
Herzzentrum Dresden, Department of Internal Medicine and Cardiology, Technische Universität Dresden, Fetscherstr. 76, 01307 Dresden, Germany.
Patients with end-stage kidney disease (ESRD) represent a high-risk population in terms of both development of and death by cardiovascular diseases. Outcome data of ESRD patients with severe aortic valve stenosis (AS) treated by transcatheter aortic valve implantation (AVI) are scarce. We aim to compare the outcome of ESRD patients undergoing transfemoral (TF) or transapical (TA) AVI.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
December 2024
Cardiology Department, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Background: The management of Transcatheter Aortic Valve Implantation (TAVI) patients with a small aortic annulus (SAA) postures a substantial challenge, increasing the risk of patient- prosthesis mismatch (PPM) and overall mortality.
Aims: This study aimed to compare the hemodynamic and clinical outcomes of transcatheter balloon-expandable valve (BEV) versus transcatheter self-expandable valve (SEV) in SAA.
Methods: We conducted propensity score matching (PSM) of severe AS patients with SAA who underwent trans-femoral TAVR and enrolled to the Israeli TAVR registry between the years 2008 and 2023.
EuroIntervention
December 2024
Harrington Heart and Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, USA.
Background: No data compare newer-generation transcatheter heart valves (THVs) in terms of next-day discharge (NDD) following transfemoral (TF) transcatheter aortic valve implantation (TAVI).
Aims: We aimed to evaluate the safety of NDD in unselected patients who received ACURATE (neo/neo2), Evolut (PRO/PRO+/FX) and the SAPIEN (3/Ultra) THVs.
Methods: This multicentre registry included patients who underwent TF-TAVI without a preprocedural permanent pacemaker implantation (PPI) and were discharged the next day without a new PPI.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!