In experimental nociception models, there is an increase in the glutamate cerebrospinal fluid (CSF) and a decrease in its levels in analgesic treatments. For the determination of glutamate in CSF, an analytical UV spectrophotometric method was developed and validated. The measurements on the UV-vis spectrophotometer were performed after the derivatization reaction of the neurotransmitter, when reading in the ultraviolet (UV) region, at the maximum absorption wavelength of 265 nm. The technique presented excellent linearity, as well as good intraday and interday precision, with coefficients of variation less than 15 %, and a correlation coefficient close to 1.0 (lower dispersion of the experimental set points and lower uncertainty of the estimated regression coefficients). The analytical conditions that were established by the ultraviolet spectrophotometric method demonstrated selectivity, linearity, precision, specificity, robustness, and accuracy. This is suitable for the quantitative determination of glutamate in the CSF. The technique developed by UV-vis spectrophotometry for glutamate dosing was fast, efficient, easy to perform, and more economically accessible when compared to current standard techniques. When comparing the data obtained in this study with the results of the official methodology, in which HPLC and spectrofluorimetry were used, it was observed that the closest values of glutamate release occurred between the spectrofluorimeter and the UV-vis spectrophotometer. The UV-vis spectrophotometry method for the determination of CSF glutamate has been shown to be accurate, reproducible, and satisfactory, making it an extremely advantageous and a viable alternative for the determination of amino acid glutamate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2020.113290 | DOI Listing |
Chemosphere
January 2025
Nanoqam, Department of Chemistry, University of Quebec at Montreal, H3C 3P8, Canada; École de technologie supérieure, Montréal (Québec), Canada, H3C 1K3. Electronic address:
Molecules
January 2025
Polymer Processing Division, Institute of Materials Technology, Faculty of Mechanical Engineering, Poznan University of Technology, Piotrowo 3, 61-138 Poznan, Poland.
Packaging materials mainly serve the function of protecting products. The most common representative of this group is poly(ethylene terephthalate) (PET), which is not biodegradable and therefore, its waste might be burdensome to the environment. Thus, this work aims to develop outlines for obtaining polyester-based systems, preferably biobased ones, intended for the packaging industry and their detailed characterization.
View Article and Find Full Text PDFMolecules
December 2024
Department of Biology, Lomonosov Moscow State University, Leninskie Gory 1-12, 119234 Moscow, Russia.
Sulfonated indocyanines 3 and 5 (sCy3, sCy5) are widely used to label biomolecules. Their high molar absorption coefficients and lack of spectral overlap with biopolymers make them ideal as linker components for rapid assessment of bioconjugate stoichiometry. We recently found that the determination of the sCy3:sCy5 molar ratio in a conjugate from its optical absorption spectrum is not straightforward, as the sCy3:sCy5 absorbance ratio at the maxima tends to be larger than expected.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
College of Resources and Environment, Southwest University, Chongqing, 400716, China; Key Laboratory of Biomedical Analytics (Southwest University), Chongqing Science and Technology Bureau, College of Pharmaceutical Sciences, Southwest University, Chongqing, 400715, China. Electronic address:
Background: Because arsenate (As(V)) is a highly toxic pollutant, timely on-site monitoring of its concentration is crucial for mitigating potential environmental and health hazards. Traditional on-site detection methods for As(V) often face limitations of long response time and low sensitivity. Nanozymes are nanomaterials that exhibit enzyme-like catalytic activity.
View Article and Find Full Text PDFAnal Chim Acta
January 2025
Wastewater Laboratory Targoviste, Water Company Targoviste-Dambovita, Calea Ploiesti Street, 130 145, Targoviste, Romania. Electronic address:
Background: The calibration curve represents the relationship between known CRM and the response of the instrument (e.g absorbance). Most of the time, in analytical chemistry standards, the linear function (of the 1st degree) is used to characterize the calibration curves.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!