Achieving diffraction-limited resolution in soft-X-ray Fourier-transform holography.

Ultramicroscopy

Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, Max-Born-Str. 2A, Berlin 12489, Germany; Technische Universität Berlin, Institut für Optik und Atomare Physik, Straße des 17. Juni 135, Berlin 10623, Germany.

Published: July 2020

The spatial resolution of microscopic images acquired via X-ray Fourier-transform holography is limited by the source size of the reference wave and by the numerical aperture of the detector. We analyze the interplay between both influences and show how they are matched in practice. We further identify, how high spatial frequencies translate to imaging artifacts in holographic reconstructions where mainly the reference beam limits the spatial resolution. As a solution, three methods are introduced based on numerical post-processing of the reconstruction. The methods comprise apodization of the hologram, refocusing via wave propagation, and deconvolution using the transfer function of the imaging system. In particular for the latter two, we demonstrate that image details smaller than the source size of the reference beam can be recovered up to the diffraction limit of the hologram. Our findings motivate the intentional application of a large reference-wave source enhancing the image contrast in applications with low photon numbers such as single-shot experiments at free-electron lasers or imaging at laboratory sources.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2020.113005DOI Listing

Publication Analysis

Top Keywords

fourier-transform holography
8
spatial resolution
8
source size
8
size reference
8
reference beam
8
achieving diffraction-limited
4
diffraction-limited resolution
4
resolution soft-x-ray
4
soft-x-ray fourier-transform
4
holography spatial
4

Similar Publications

Adaptive mode-selective multiplexers offer the potential to control the modal content within multimode fibers for space division multiplexing (SDM). To such an end, spatial light modulators allow programmable control over the phase, amplitude, and polarization of optical wavefronts. One of the major challenges is to precisely match the manipulated beam to the waveguide modes in the multimode fiber.

View Article and Find Full Text PDF

Linear digital filters are at the core of image reconstruction and processing for many coherent optical imaging techniques, such as digital holography (DH) or optical coherence tomography (OCT). They can also be efficiently implemented using fast Fourier transform (FFT) with appropriate transfer/filter functions that operate in the frequency domain. However, even with optimal filter design, they suffer from side effects such as sidelobe generation or resolution limitations, e.

View Article and Find Full Text PDF

Spectroscopic aspects of underwater digital holography of plankton.

Sci Rep

January 2025

Laboratory for Radiophysical and Optical Methods of Environmental Research, National Research Tomsk State University, Tomsk, Russia, 634050.

Monitoring the parameters and behavior of plankton makes it possible to assess the state of the aquatic ecosystem and detect the beginning of an environmental disaster at an early stage. In this respect, the most informative method for the in situ plankton study is underwater digital holography. This method allows obtaining information on the size, shape, and location of plankton individuals, as well as performing their classification and biotesting according to their behavioral responses using a submersible holographic camera non-invasively, in real time, and in the automatic mode.

View Article and Find Full Text PDF

We propose a multi-wavelength digital holography based on Kramers-Kronig (KK) relations, introducing a unified angle-multiplexing multi-wavelength KK model to overcome the accuracy and resolution limitations of angle-multiplexing techniques. By linking the real and imaginary parts of the multi-wavelength complex function via the KK relation, the method captures object light waves with the full effective bandwidth from a single interferogram and reference wave intensity. This method greatly improves spectral utilization and measurement accuracy in multi-wavelength interference.

View Article and Find Full Text PDF

Extreme ultraviolet pulses as generated by high harmonic generation (HHG) are a powerful tool for both time-resolved spectroscopy and coherent diffractive imaging. However, the integration of spectroscopy and microscopy to harness the unique broadband spectra provided by HHG is hardly explored due to the challenge to decouple spectroscopic and microscopic information. Here, we present an interferometric approach to this problem that combines Fourier transform spectroscopy (FTS) with Fourier transform holography (FTH).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!