Background: In ACL repair, full-length single-diameter tunnels facilitate anatomic femoral fixation with suspensory devices, especially with outside-in techniques, and are required after accidental cortical perforation. With tunnel diameters over 6 mm, fixation resistance using regular suspensory devices may not suffice. Oversized cortical footprint devices could be a solution to guarantee fixation performance in larger tunnel diameters. This study aims to assess the biomechanical properties of ACL femoral fixation provided by two enlarged suspensory devices of similar characteristics, a fixed loop (G-Lok™ with G-Lok-XL™) and an adjustable loop (ProCinch™ with G-Lok-XL™), resting on a full-length 9 mm diameter tunnel compared to the widely accepted regular fixed-loop device (G-Lok™) on a socket tunnel.

Methods: Twenty-seven fresh frozen porcine femurs and flexor digitorum profundus tendons were randomly assigned to a study group depending on the fixation method used (N = 9). Graft-femur constructs were subjected to a traction cyclic test (5000 cycles, [50-250]N load, 1 Hz) followed by a load-to-failure test (v = 1 mm/s). Residual displacement during the cyclic test and stiffness, displacements at physiological loads, ultimate load and corresponding displacement during the load-to-failure test were determined.

Findings: No significant differences could be established for any parameter measured in the comparison between the control with the socket tunnel and the oversized fixations with full-length tunnels.

Interpretation: ACL femoral fixation achieved in full-length single diameter tunnels by using an enlarged suspension device, both with a fixed or an adjustable loop, provide similar biomechanical properties to the gold-standard fixed-loop device in a socket tunnel. Therefore, its clinical use may be safe.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2020.105008DOI Listing

Publication Analysis

Top Keywords

suspensory devices
16
femoral fixation
12
tunnel diameters
8
biomechanical properties
8
acl femoral
8
adjustable loop
8
fixed-loop device
8
cyclic test
8
load-to-failure test
8
socket tunnel
8

Similar Publications

Introduction: This study aims to evaluate the effects of adjustable- and fixed-loop femoral endobuttons on intraoperative surgeon satisfaction and postoperative patient functional outcomes in anterior cruciate ligament (ACL) reconstruction. The use of cortical suspensory devices, either fixed-loop or adjustable-loop, is common in ACL reconstruction surgeries for femoral tunnel fixation. Fixed-loop devices, although effective, often require additional tunnel drilling, potentially leading to tunnel widening.

View Article and Find Full Text PDF

Changes in Biomarkers of Inflammation and Oxidative Status in Dogs Subjected to Celiotomy or Video-Assisted Ovariohysterectomy.

Vet Sci

November 2024

Programa de Pós-Graduação em Medicina Veterinária (PPGMV), Universidade Federal de Santa Maria (UFSM), Santa Maria 97105-900, Brazil.

We evaluated the surgical stress response of dogs undergoing three ovariohysterectomy (OVH) techniques. Twenty-nine healthy females were allocated into groups: celiotomy and ligature (CelioSut), celiotomy and bipolar energy (CelioBip), and a video-assisted technique using two portals and bipolar energy (VidBip). Clinical evaluation was performed, and the following blood analyses were determined: acute phase proteins (C-reactive protein and haptoglobin), white blood cell counting (WBC), and biomarkers of oxidative status.

View Article and Find Full Text PDF

Multiple disruptions of superior suspensory shoulder complex: A case report.

Int J Surg Case Rep

November 2024

Upper Extremities Surgery and Sports Medicine Department, Viet Duc University Hospital, Hanoi, Viet Nam.

Article Synopsis
  • The superior shoulder suspensory complex (SSSC) is crucial for shoulder stability and is made up of multiple structures, including bones and ligaments; disruption of two or more leads to instability.
  • A 43-year-old woman experienced a rare case of triple disruption involving her acromion, coracoid process, and acromioclavicular joint after a car accident, requiring surgical intervention.
  • Treatment options vary for SSSC disruptions, with K-wire fixation chosen because of the patient’s smaller acromion size, emphasizing the need for personalized surgical approaches based on the injury specifics.
View Article and Find Full Text PDF
Article Synopsis
  • Advances in using quadriceps tendon autografts for ACL reconstruction have increased interest due to their favorable collagen properties, but the biomechanics of different fixation techniques remain unclear.
  • This study aimed to compare the biomechanics of various suspensory techniques for securing soft tissue QT autografts in an ACL reconstruction model.
  • Results showed that the tape-reinforced (TR) group had significantly better performance, with less tension loss and cyclic elongation than other techniques, while all techniques maintained stiffness and ultimate load capabilities above typical ACL limits.
View Article and Find Full Text PDF

Anterior cruciate ligament reconstruction (ACLR) using double adjustable fixation gained popularity in the last decade due to its minimally invasive technique. However, suspensory fixation devices could be related to recurrent instability, poor clinical outcomes, and patient dissatisfaction. The present study aims to evaluate the clinical outcomes following ACLR using double adjustable-loop suspensory fixation devices in the demanding population of young patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!