To prospectively compare three image acquisition techniques in lower extremity CT angiography: the "standard" anterograde technique (SA), the adaptive anterograde technique (AA), and the retrograde acquisition technique (RA). Sixty consecutive patients were prospectively enrolled and randomized into three acquisition groups: 20 patients were evaluated with SA, 20 with AA as described by Qanadli et al., and 20 with caudocranial acquisition from the feet to the abdominal aorta (RA). Quantitative image quality was assessed by measuring the intraluminal attenuation at different levels of interest, with a total of 536 levels. Qualitative image quality was assessed by two radiologists in consensus using a Likert scale to rate the arterial enhancement and venous return. For each patient and limb, the presence of occlusive or aneurysmal disease was documented. In quantitative analysis, RA showed lower attenuation values than SA and AA ( < 0.01). AA showed the highest and most homogeneous attenuation along the arterial tree. In qualitative analysis, AA had the lowest rate of non-diagnostic vascular segments (3.9%) compared to SA and RA (4.7 and 13.1%, respectively, < 0.01). The influence of venous return was significantly different among the different techniques; venous contamination was particularly prevalent at the aortic level with RA (9.4% of patients, 0% with SA and AA, < 0.01). The presence of stenosis or occlusion had no significant influence on the attenuation values across all levels and acquisition techniques. Conversely, the presence of aneurysmal disease had a significant effect on the luminal attenuation in AA (higher attenuation) and RA (lower attenuation) at the iliac ( = 0.03 and 0.04, respectively) and femoral levels ( = 0.02 and <0.01, respectively). Considering both quantitative and qualitative analysis, AA performed better than SA and RA, providing the highest percentage of optimal vascular enhancement. AA should be recommended as the technique of choice, specifically in the presence of aneurysmal disease. Alternatively, SA can be useful in case of renal failure, as the test bolus is unnecessary. Finally, the increasing availability of fast CT systems will likely overcome the limitations of RA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7198850PMC
http://dx.doi.org/10.3389/fcvm.2020.00068DOI Listing

Publication Analysis

Top Keywords

acquisition techniques
12
three image
8
image acquisition
8
anterograde technique
8
image quality
8
quality assessed
8
venous return
8
aneurysmal disease
8
lower attenuation
8
attenuation values
8

Similar Publications

Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction.

BMC Med Imaging

January 2025

Department of Magnetic Resonance Imaging, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, 450052, China.

Background: Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.

View Article and Find Full Text PDF

The brain is composed of a dense and ramified vascular network of arteries, veins and capillaries of various sizes. One way to assess the risk of cerebrovascular pathologies is to use computational models to predict the physiological effects of reduced blood supply and correlate these responses with observations of brain damage. Therefore, it is crucial to establish a detailed 3D organization of the brain vasculature, which could be used to develop more accurate in silico models.

View Article and Find Full Text PDF

Background: Antiangiogenic inhibitors plus immune checkpoint inhibitors have synergistic antitumor activity and have improved treatment outcomes in patients with renal cell carcinoma (RCC).

Objective: We report the RCC cohort from a phase Ib/II study in Chinese patients evaluating the efficacy and safety of fruquintinib plus sintilimab in treating advanced clear cell RCC (ccRCC).

Patients And Methods: Eligible patients had pathologically confirmed advanced ccRCC.

View Article and Find Full Text PDF

Aims: Establishment of a protocol for routine single-molecule localisation microscopy (SMLM) imaging on formalin fixed paraffin embedded (FFPE) tissue using medical renal disease including minimal change disease (MCD) and focal segmental glomerulosclerosis (FSGS).

Methods: Protocol for normal and diseased renal FFPE tissue was developed to investigate the clinical diagnostic potential of SMLM. Antibody concentrations were determined for confocal microscopy and transferred to SMLM.

View Article and Find Full Text PDF

Background And Purpose: Magnetic Resonance Imaging is widely used to assess disease burden in multiple sclerosis (MS). This study aimed to evaluate the effectiveness of a commercially available k-nearest neighbors (k-NN) software in quantifying white matter lesion (WML) burden in MS. We compared the software's WML quantification to expert radiologists' assessments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!