Many previous studies have shown that the remote photoplethysmography (rPPG) can measure the Heart Rate (HR) signal with very high accuracy. The remote measurement of the Pulse Rate Variability (PRV) signal is also possible, but this is much more complicated because it is then necessary to detect the peaks on the temporal rPPG signal, which is usually quite noisy and has a lower temporal resolution than PPG signals obtained by contact equipment. Since the PRV signal is vital for various applications such as remote recognition of stress and emotion, the improvement of PRV measurement by rPPG is a critical task. Contact based PRV measurement has already been investigated, but the research on remotely measured PRV is very limited. In this paper, we propose to use the Periodic Variance Maximization (PVM) method to extract the rPPG signal and event-related Two-Window algorithm to improve the peak detection for PRV measurement. We have made several contributions. Firstly, we show that the newly proposed PVM method and Two-Window algorithm can be used for PRV measurement in the non-contact scenario. Secondly, we propose a method to adaptively determine the parameters of the Two-Window method. Thirdly, we compare the algorithm with other attempts for improving the non-contact PRV measurement such as the Slope Sum Function (SSF) method and the Local Maximum method. We calculated several features and compared the accuracy based on the ground truth provided by contact equipment. Our experiments showed that this algorithm performed the best of all the algorithms.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7294433 | PMC |
http://dx.doi.org/10.3390/s20102752 | DOI Listing |
Porcine circovirus type 2 (PCV2) is the major causative agent of postweaning multisystemic wasting syndrome which leads to significant economic losses in the global swine industry. In China, there is a widespread dissemination of PCV2 infection in the pig population. Serological diagnosis of the disease is considered as an effective control measure.
View Article and Find Full Text PDFVet Microbiol
February 2025
College of Animal Science and Technology, Anhui Agricultural University, Hefei, Anhui 230036, China; Joint Research Center for Food Nutrition and Health of IHM, Anhui Agricultural University, Hefei, China. Electronic address:
Pseudorabies virus (PRV) is a significant pathogen that causes acute infectious diseases in pigs, resulting in considerable economic losses for the global pig industry. The lack of effective control measures and vaccines against the circulating variants of PRV highlights the pressing need for novel treatment strategies. In this study, a screening of a natural product library identified Berbamine as a promising compound that inhibits PRV replication, with a selectivity index of 17.
View Article and Find Full Text PDFJ Am Soc Echocardiogr
December 2024
Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN; Mayo Clinic School of Medicine, Mayo Clinic College of Medicine and Science, Mayo Clinic, Rochester, MN.
Exercise intolerance is a hallmark symptom in adults with repaired tetralogy of Fallot (TOF). This may be attributed to the disease-related impairment in RV systolic function, augmentation in right ventricular (RV) load, and their combined effect on altering left ventricular (LV) hemodynamics. To further elucidate these mechanisms, we examined oxygen uptake (VO) by indirect-calorimetry and cardiac hemodynamics by echocardiography in 34 TOF (48 ± 14 yrs) and 29 healthy controls (41 ± 15 yrs), at rest and during exercise.
View Article and Find Full Text PDFCurr Microbiol
December 2024
Advanced Centre for Plant Virology, Division of Plant Pathology, ICAR-Indian Agricultural Research Institute, New Delhi, 110012, India.
Novel viruses in plants can be detected through transcriptome data mining. In this study, a novel cytorhabdovirus, pear rhabdovirus 1 (PRV-1) was identified through reanalysis of RNA-seq data of pear (P. communis 'Bartlett').
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
March 2025
Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, Św. A. Boboli 8 St., Warsaw 02-525, Poland. Electronic address:
Multi-wavelength plethysmography (MWPPG) is a growing technique for noninvasive hemodynamic measurements, particularly spectral based methods. Different wavelengths have been investigated for both transmissive and reflectance PPG configurations. The objective of this work is to investigate the feasibility of Diffuse Transmittance Spectroscopy (DTS) for Pulse Rate Variability (PRV) measurements and to evaluate the performance of diffuse transmittance spectroscopy in quantifying ultrashort pulse rate variability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!