Importance: Rates of chlamydial and gonococcal infection continue to increase in the United States, as do the associated costs of untreated infections. Improved diagnostic technologies that support testing and treating in 1 clinical visit are critical to advancing efforts to control the rates of chlamydial and gonococcal infection.

Objective: To evaluate the clinical performance of a point-of-care (POC) molecular diagnostic assay for the detection of chlamydia and gonorrhea.

Design, Setting, And Participants: A noninterventional, cross-sectional clinical study was conducted from September 18, 2018, through March 13, 2019, at sexually transmitted infection (STI), HIV, family planning, and obstetrics and gynecology clinics where STI screening is routine, using a convenience sample and comparing commercially available assays with a new 30-minute POC assay. Patients included were those eligible for STI screening or diagnostic testing who had not taken antibiotics effective against chlamydia or gonorrhea within the previous 28 days. Four vaginal swab samples were collected from women and a first-catch urine sample was obtained from men.

Main Outcomes And Measures: A composite infection status was used to classify participants as infected if 2 or more comparator results were positive, as not infected if 2 or more comparator samples were negative, and as unevaluable if 1 result was invalid and the other 2 results did not agree with each other.

Results: Swab samples from 1523 women (median age, 27 years [interquartile range, 17-37 years]), 817 (53.6%) of whom presented with symptoms, and 922 men (median age, 29 years [interquartile range, 17-41 years]), 308 (33.4%) of whom were symptomatic, were tested. For chlamydia, sensitivity of the new POC assay was 96.1% (95% CI, 91.2%-98.3%) for women and 92.5% (95% CI, 86.4%-96.0%) for men. For gonorrhea, sensitivity estimates were 100.0% (95% CI, 92.1%-100.0%) for women and 97.3% (95% CI, 90.7%-99.3%) for men. For chlamydia, specificity of the new POC assay was 99.1% (95% CI, 98.4%-99.5%) for women and 99.3% (95% CI, 98.4%-99.7%) for men. For gonorrhea, specificity estimates were 99.9% (95% CI, 99.5%-100%) for women and 100% (95% CI, 95.5%-100%) for men. Non-laboratory-trained personnel performed 94.8% of all tests (2318 of 2445) during the study.

Conclusions And Relevance: This study suggests that self-obtained vaginal swab samples were associated with performance equivalent to laboratory-based molecular diagnostics, which can support use of this POC assay in many settings. The availability of an easy-to-use, rapid (30-minute) molecular test for accurate detection of chlamydia and gonorrhea has the power to facilitate testing and treatment in a single patient visit for these STIs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7225902PMC
http://dx.doi.org/10.1001/jamanetworkopen.2020.4819DOI Listing

Publication Analysis

Top Keywords

poc assay
16
chlamydia gonorrhea
12
swab samples
12
performance point-of-care
8
rates chlamydial
8
chlamydial gonococcal
8
detection chlamydia
8
sti screening
8
vaginal swab
8
infected comparator
8

Similar Publications

Soil microorganisms transform plant-derived C (carbon) into particulate organic C (POC) and mineral-associated C (MAOC) pools. While microbial carbon use efficiency (CUE) is widely recognized in current biogeochemical models as a key predictor of soil organic carbon (SOC) storage, large-scale empirical evidence is limited. In this study, we proposed and experimentally tested two predictors of POC and MAOC pool formation: microbial necromass (using amino sugars as a proxy) and CUE (by O-HO approach).

View Article and Find Full Text PDF

Background: High blood pressure is a prevalent condition in patients with chronic kidney disease on hemodialysis. Adequate control of high blood pressure is essential to reducing deaths in this group. The present study aimed to observe mortality prospectively in a group of patients in hemodialysis and hemodiafiltration programs in whom the use of antihypertensives was optimized with the point-of-care dry weight (POC-DW) technique.

View Article and Find Full Text PDF

It has been debated whether endometriosis (EMS) adversely affects oocyte quality, potentially leading to a higher incidence of genetically unbalanced embryos or other egg factors that affect the developmental potential. In this study, we explored the effects of endometriosis on risk of chromosomally aberrant in miscarried products of conception (POC) after assisted reproductive treatment (ART), including fresh and frozen cycles. Miscarried POCs were collected from EMS patients (N = 102) and non-EMS patients (N = 441).

View Article and Find Full Text PDF

Objectives: Evaluation of diagnostic accuracy of two point-of-care (POC) molecular diagnostic tests for the detection of monkeypox virus (MPXV): Xpert® Mpox (Cepheid, Inc., USA) and STANDARD™ M10 MPX/OPX (SD Biosensor, Inc., Korea).

View Article and Find Full Text PDF

Understanding the accumulation and stability of soil organic matter (SOM) pools as a function of time (i.e., soil age) and climate (i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!