During general anesthesia (GA), direct analysis of arterial pressure or aortic flow waveforms may be inconclusive in complex situations. Patient-specific biomechanical models, based on data obtained during GA and capable to perform fast simulations of cardiac cycles, have the potential to augment hemodynamic monitoring. Such models allow to simulate Pressure-Volume (PV) loops and estimate functional indicators of cardiovascular (CV) system, e.g. ventricular-arterial coupling (Vva), cardiac efficiency (CE) or myocardial contractility, evolving throughout GA. In this prospective observational study, we created patient-specific biomechanical models of heart and vasculature of a reduced geometric complexity for n = 45 patients undergoing GA, while using transthoracic echocardiography and aortic pressure and flow signals acquired in the beginning of GA (baseline condition). If intraoperative hypotension (IOH) appeared, diluted norepinephrine (NOR) was administered and the model readjusted according to the measured aortic pressure and flow signals. Such patients were a posteriori assigned into a so-called hypotensive group. The accuracy of simulated mean aortic pressure (MAP) and stroke volume (SV) at baseline were in accordance with the guidelines for the validation of new devices or reference measurement methods in all patients. After NOR administration in the hypotensive group, the percentage of concordance with 10% exclusion zone between measurement and simulation was >95% for both MAP and SV. The modeling results showed a decreased Vva (0.64±0.37 vs 0.88±0.43; p = 0.039) and an increased CE (0.8±0.1 vs 0.73±0.11; p = 0.042) in hypotensive vs normotensive patients. Furthermore, Vva increased by 92±101%, CE decreased by 13±11% (p < 0.001 for both) and contractility increased by 14±11% (p = 0.002) in the hypotensive group post-NOR administration. In this work we demonstrated the application of fast-running patient-specific biophysical models to estimate PV loops and functional indicators of CV system using clinical data available during GA. The work paves the way for model-augmented hemodynamic monitoring at operating theatres or intensive care units to enhance the information on patient-specific physiology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7224549PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0232830PLOS

Publication Analysis

Top Keywords

patient-specific biomechanical
12
aortic pressure
12
hypotensive group
12
general anesthesia
8
biomechanical models
8
hemodynamic monitoring
8
functional indicators
8
pressure flow
8
flow signals
8
patient-specific
5

Similar Publications

: We aimed to predict patient-specific rupture risks and growth behaviors in abdominal aortic aneurysm (AAA) patients using biomechanical evaluation with finite element analysis to establish an additional AAA repair threshold besides diameter and sex. : A total of 1219 patients treated between 2005 and 2024 (conservative and repaired AAAs) were screened for a pseudo-prospective single-center study. A total of 15 ruptured (rAAA) vs.

View Article and Find Full Text PDF
Article Synopsis
  • Scoliosis is identified through Cobb's angle, and this study aims to create a digital twin of the spine to analyze biomechanical stresses and disc degeneration related to idiopathic scoliosis using patient-specific data.
  • A 3D computational model was developed that modifies intervertebral disc properties based on radiological measurements, validated by comparing with patient images; finite element analysis clarified the impact of deformity on spinal biomechanics.
  • The results showed that the model accurately represented thoracic scoliosis and revealed that disc strain increases near the apex, with "type-C" curves at higher risk for herniation compared to "type-S," thereby enhancing understanding of scoliosis and aiding in treatment planning.
View Article and Find Full Text PDF

Accurate calibration of finite element (FE) models is essential across various biomechanical applications, including human intervertebral discs (IVDs), to ensure their reliability and use in diagnosing and planning treatments. However, traditional calibration methods are computationally intensive, requiring iterative, derivative-free optimization algorithms that often take days to converge. This study addresses these challenges by introducing a novel, efficient, and effective calibration method demonstrated on a human L4-L5 IVD FE model as a case study using a neural network (NN) surrogate.

View Article and Find Full Text PDF

Orthopedic surgery and traumatology necessitate cost-effective approaches that can be replicated across multiple venues. Finite Element (FE) simulation models have evolved as a solution, allowing for consistent investigations into biomechanical systems. Finite Element Analysis (FEA), which began in the 1950s aviation industry, has since expanded into orthopedics.

View Article and Find Full Text PDF

Purpose Of Review: With the growing popularity and broadening indications for Reverse Shoulder Arthroplasty (RSA), increasing modularity in design and adjustments to each component can enhance postoperative range of motion (ROM), thus expanding treatment capabilities. This review outlines the advancements developed to optimize ROM through modifications in glenoid and humeral components and the integration of computational tools for surgical planning.

Recent Findings: Enhancements in glenoid component design aim to mitigate complications like scapular notching and improve ROM, particularly in abduction and external rotation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!