Significance: Noninvasive in vivo fast pulsatile blood flow measurement in deep tissue is important because the blood flow waveform is correlated with physiological parameters, such as blood pressure and elasticity of blood vessels. Compromised blood flow may cause diseases, such as stroke, foot ulcer, and myocardial ischemia. There is great clinical demand for a portable and cost-effective device for noninvasive pulsatile blood flow measurement.

Aim: A diffuse-optics-based method, diffuse speckle pulsatile flowmetry (DSPF), was developed for fast measurement (∼300  Hz) of deep tissue blood flow noninvasively. To validate its performance, both a phantom experiment and in vivo demonstration were conducted.

Approach: Over the past two decades, single-mode fibers have been used as detection fibers in most diffuse-optics-based deep tissue blood flow measurement modalities. We used a multimode (MM) detection fiber with a core size of 200  μm for diffused speckle pattern detection. A background intensity correction algorithm was implemented for speckle contrast calculation. The MM detection fiber helped to achieve a level of deep tissue blood flow measurement similar to that of conventional modalities, such as diffuse correlation spectroscopy and diffuse speckle contrast analysis, but it increases the measurement rate of blood flow to 300 Hz.

Results: The design and implementation of the DSPF system were introduced. The theory of the background intensity correction for the diffused speckle pattern detected by the MM fiber was explained. A flow phantom was built for validation of the performance of the DSPF system. An in vivo cuff-induced occlusion experiment was performed to demonstrate the capability of the proposed DSPF system.

Conclusions: An MM detection fiber can help to achieve fast (∼300  Hz) pulsatile blood flow measurement in the proposed DSPF method. The cost-effective device and the fiber-based flexible probe increase the usability of the DSPF system significantly.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219964PMC
http://dx.doi.org/10.1117/1.JBO.25.5.055003DOI Listing

Publication Analysis

Top Keywords

blood flow
40
flow measurement
20
deep tissue
20
pulsatile blood
16
detection fiber
16
tissue blood
16
blood
12
dspf system
12
flow
11
fast pulsatile
8

Similar Publications

Background: The traditional use of Moringa oleifera (MO), an essential food source in Africa and Asia, to cure various diseases dates back thousands of years. This study examines the aqueous and ethanolic leaf extracts of MO's in vitro anti-leukemia capabilities.

Methods: After preparing aqueous and ethanolic MO leaf extracts, cells were treated with various concentrations for 48 h.

View Article and Find Full Text PDF

Predicting the evolution of ascending aortic aneurysm (AscAA) growth is a challenge, complicated by the intricate interplay of aortic geometry, tissue behavior, and blood flow dynamics. We investigate a flow-structural growth and remodeling (FSG) model based on the homogenized constrained mixture theory to simulate realistic AscAA growth evolution. Our approach involves initiating a finite element model with an initial elastin insult, driven by the distribution of Time-Averaged Wall Shear Stress (TAWSS) derived from computational fluid dynamics simulations.

View Article and Find Full Text PDF

Background: Over the last decade, the anticancer effects of Stokes (RVS) have been reported in various preclinical or clinical studies. However, the effects of RVS on immuno-oncology, especially on the functional properties of T cells and their phenotypes, remain unclear. Here, we planned to investigate the impact of RVS on immuno-oncology, specifically focusing on its effects on T cells.

View Article and Find Full Text PDF

Application of Laparoscopic Partial Splenectomy with Total Blood Flow Occlusion in Benign Splenic Lesions.

J Vis Exp

December 2024

Department of Hepatobiliary and Pancreatic-Spleen Surgery, Shunde Hospital of Southern Medical University, First People's Hospital of Shunde;

Laparoscopic partial splenectomy (LPS) is gradually becoming the preferred method for treating benign splenic lesions. However, due to the abundant blood supply and its soft, fragile tissue texture, especially when the lesion is located near the splenic hilum or is particularly large, performing partial splenectomy (PS) in clinical practice is extremely challenging. Therefore, we have been continuously exploring and optimizing hemorrhage control methods during PS, and we here propose a method to perform LPS with complete spleen blood flow occlusion.

View Article and Find Full Text PDF

The Coombs test is important in hematology for detecting erythrocyte-bound IgG antibodies or in serm through agglutination methods, but its sensitivity and specificity are limited. Flow cytometry provides a more precise and sensitive alternative for quantitatively assessing RBC-bound IgG antibodies. This assessment is crucial for evaluating the risk of hemolytic reactions and ensuring safe transfusions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!