The purpose of this study is to investigate the precision and trueness of the occlusal contact record obtained with a dental CAD/CAM device (ARCTICA). Sandblasted spherical steel balls with diameters of 10-20 mm were measured using ARCTICA and a three-dimensional measurement device (FN503). The radius of each steel ball was calculated from the measured value and the difference between the measured and nominal values was obtained. Upper/lower dental arch casts were measured and processed for occlusal contact image creation using both devices. The graphical images of the occlusal contacts at the intercuspal position obtained from both systems and an occlusal analysis device (BE-1) were compared with the occlusal contact area. Excellent correlation was observed between the measurement results of ARCTICA and FN503 (p<0.001, R: 0.99). The occlusal contact areas were 186.0 mm (ARCTICA), 192.8 mm (FN503), and 196.1 mm (BE-1). This study showed that ARCTICA is capable of conducting highly accurate measurements and generating a graphical image of occlusal contacts with good reliability.

Download full-text PDF

Source
http://dx.doi.org/10.4012/dmj.2019-157DOI Listing

Publication Analysis

Top Keywords

occlusal contact
12
dental cad/cam
8
occlusal
5
evaluation measurement
4
measurement precision
4
precision accuracy
4
accuracy dental
4
cad/cam system
4
system purpose
4
purpose study
4

Similar Publications

The technical development of implant-supported fixed dental prostheses (iFDP) initially concentrated on the computer-aided manufacturing of prosthetic restorations (CAM). Advances in information technologies have shifted the focus for optimizing digital workflows to AI-based processes for design (CAD). This pre-clinical pilot trial investigated the feasibility of the automatic design of three-unit iFDPs using CAD software (Dental Manger 2021, 3Shape; DentalCAD 3.

View Article and Find Full Text PDF

Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time: An Study.

J Contemp Dent Pract

September 2024

Department of Preventive and Restorative Dentistry, School of Dental Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.

Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators.

Materials And Methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency.

View Article and Find Full Text PDF

Background: Different protocols exist regarding wear time of invisible aligners. There is no study that compared the effect of different protocols. The aim of this study was to assess the effect of Invisalign aligners in four first-premolar extraction treatments in adolescents using three aligner wear protocols, every 7, 10 and 14 days.

View Article and Find Full Text PDF

Aim: Aberrative occlusal contacts were associated with Temporomandibular disorder (TMD), but whether stabilization splints with therapeutic exercises alleviate the symptoms is unclear. Hence, this study aims to compare the short-term efficacy of occlusal splint therapy and the synergistic effect of therapeutic exercise with occlusal splint therapy for 3 weeks in individuals with TMD.

Settings And Design: in-vivo observational pilot study.

View Article and Find Full Text PDF

Occlusion plays a crucial role in the long-term success and functionality of dental restorations. The purpose of this study was to investigate the changes in occlusal contacts upon the cementation of zirconia crowns with different cement spacer settings in computer-aided design and computer-aided manufacturing (CAD-CAM) software (3Shape Dental System version 2.102.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?