Objectives: To investigate whether the use of graduated compression stockings (GCS) offers any adjuvant benefit when pharmaco-thromboprophylaxis is used for venous thromboembolism prophylaxis in patients undergoing elective surgery.

Design: Open, multicentre, randomised, controlled, non-inferiority trial.

Setting: Seven National Health Service tertiary hospitals in the United Kingdom.

Participants: 1905 elective surgical inpatients (≥18 years) assessed as being at moderate or high risk of venous thromboembolism were eligible and consented to participate.

Intervention: Participants were randomly assigned (1:1) to receive low molecular weight heparin (LMWH) pharmaco-thromboprophylaxis alone or LMWH pharmaco-thromboprophylaxis and GCS.

Outcome Measures: The primary outcome was imaging confirmed lower limb deep vein thrombosis with or without symptoms, or pulmonary embolism with symptoms within 90 days of surgery. Secondary outcome measures were quality of life, compliance with stockings and LMWH, lower limb complications related to GCS, bleeding complications, adverse reactions to LMWH, and all cause mortality.

Results: Between May 2016 and January 2019, 1905 participants were randomised. 1858 were included in the intention to treat analysis (17 were identified as ineligible after randomisation and 30 did not undergo surgery). A primary outcome event occurred in 16 of 937 (1.7%) patients in the LMWH alone group compared with 13 of 921 (1.4%) in the LMWH and GCS group. The risk difference between the two groups was 0.30% (95% confidence interval -0.65% to 1.26%). Because the 95% confidence interval did not cross the non-inferiority margin of 3.5% (P<0.001 for non-inferiority), LMWH alone was confirmed to be non-inferior.

Conclusions: For patients who have elective surgery and are at moderate or high risk of venous thromboembolism, administration of pharmaco-thromboprophylaxis alone is non-inferior to a combination of pharmaco-thromboprophylaxis and GCS. These findings indicate that GCS might be unnecessary in most patients undergoing elective surgery.

Trial Registration: ISRCTN13911492.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7219517PMC
http://dx.doi.org/10.1136/bmj.m1309DOI Listing

Publication Analysis

Top Keywords

graduated compression
8
compression stockings
8
elective surgical
8
randomised controlled
8
venous thromboembolism
8
lmwh pharmaco-thromboprophylaxis
8
primary outcome
8
lower limb
8
95% confidence
8
confidence interval
8

Similar Publications

Background: The accuracy of mammography in breast cancer screening is influenced by different factors such as breast composition. However, previous studies did not evaluate the impact of breast size on examination accuracy. This study aimed to investigate the influence of breast size on the accuracy of mammography and ultrasonography in breast cancer screening using compressed breast thickness (CBT) on mammography as an indicator of breast size.

View Article and Find Full Text PDF

Prenatal exposure to polychlorinated biphenyls (PCBs) has a detrimental effect on early cognitive development. Based on these observations, some researchers suggested that prenatal exposure to PCB may be an environmental cause of autism spectrum disorder (ASD). To investigate the potential link between prenatal exposure to PCB, we analyzed the link between the level of prenatal PCB exposure and ASD risk evaluated at 18 months of age and behavioral problems at 5 years old based on longitudinal birth cohort data collected in urban areas in Japan based on the data from 115 mother-infant pairs.

View Article and Find Full Text PDF

The mechanical behavior and fracture mechanisms of deep fractured rocks under explosive dynamic loads are critical for understanding rock instability in engineering applications such as blasting operations. This study aims to investigate how the presence of pre-existing cracks and different stress states affect the mechanical properties and fracture patterns of rock-like specimens under dynamic loading conditions. We utilized a Split Hopkinson Pressure Bar (SHPB) with an active confining pressure loading device to conduct impact compression tests on rock-like specimens containing pre-existing cracks.

View Article and Find Full Text PDF

Vertebral collapse (VC) following osteoporotic vertebral compression fracture (OVCF) often requires aggressive treatment, necessitating an accurate prediction for early intervention. This study aimed to develop a predictive model leveraging deep neural networks to predict VC progression after OVCF using magnetic resonance imaging (MRI) and clinical data. Among 245 enrolled patients with acute OVCF, data from 200 patients were used for the development dataset, and data from 45 patients were used for the test dataset.

View Article and Find Full Text PDF

Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!