A novel photonic approach for simultaneously measuring both the Doppler frequency shift (DFS) and the angle of arrival (AOA) of a microwave signal in a radar system is presented. It has the same structure as a fiber optic link consisting of a laser, an optical modulator and a photodetector. The incoming microwave signal and a reference signal are applied to the optical modulator. Beating of the echo and reference signal sidebands at the photodetector generates a low-frequency electrical signal. The DFS and the AOA can be determined from the frequency and the power of the low-frequency electrical signal measured on an electrical spectrum analyzer. The system has a very simple structure and is low-cost. It has a wide operating frequency range and a robust performance. Experimental results demonstrate a DFS measurement at around 15 GHz with errors of less than ±0.2 Hz, and a 0° to 90° AOA measurement with less than ±1° errors.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.389439DOI Listing

Publication Analysis

Top Keywords

doppler frequency
8
frequency shift
8
angle arrival
8
microwave signal
8
optical modulator
8
reference signal
8
low-frequency electrical
8
electrical signal
8
signal
6
simple photonics-based
4

Similar Publications

Middle Ear Mechanics in the Barn Owl.

J Morphol

January 2025

Department of Zoology, Denver Museum of Nature & Science, Denver, Colorado, USA.

The barn owl is a common research subject in auditory science due to its exceptional capacity for high frequency hearing and superb sound source localization capabilities. Despite longstanding interest in the auditory performance of barn owls, the function of its middle ear has attracted remarkably little attention. Here, we report the middle ear transfer function measured by laser Doppler vibrometry and direct measurements of inner ear pressures.

View Article and Find Full Text PDF

Quantification of valvular regurgitation by transthoracic 3D high pulse repetition frequency Doppler echocardiography.

Eur Heart J Imaging Methods Pract

July 2024

Department of Circulation and Medical Imaging, Faculty of Medicine and Health Science, Norwegian University of Science and Technology (NTNU), Prinsesse Kristinas gate 3, Trondheim 7030, Norway.

Aims: To improve quantification of valvular regurgitation, a 3D high-pulse repetition frequency Doppler (3D HPRFD) method was developed for regurgitant volume (RVol) estimation from transthoracic echocardiography (TTE). Although successfully applied and in selected clinical cases, a systematic clinical validation of 3D HPRFD has not been published. Hence, our aims were to investigate (i) feasibility of 3D HPRFD and (ii) correlation between 3D HPRFD and RVol estimates obtained by the 2D proximal isovelocity surface area (PISA) method and cardiac magnetic resonance (CMR) in patients with either aortic regurgitation (AR) or mitral regurgitation (MR).

View Article and Find Full Text PDF

Introduction: Ischemic stroke in patients with a systemic tumor disease or cancer not in remission (active tumors) is less well understood. Some aspects of such paraneoplastic strokes remind on a generalized cerebrovascular disorder. We hypothesized that cerebrovascular regulation in active tumor patients with a stroke is different from other patients with stroke who have no active tumor disease.

View Article and Find Full Text PDF

Experimental research on remote non-contact laser vibration measurement for tunnel lining cavities.

Sci Rep

January 2025

State Key Laboratory of Mountain Bridge and Tunnel Engineering, College of Civil Engineering, Chongqing Jiaotong University, Chongqing, 400074, China.

The lining cavities in tunnels have strong concealment and pose significant risks, seriously affecting tunnel operational safety. Therefore, it is necessary to develop efficient and high-precision detection techniques for tunnel lining cavities. In this study, concrete slabs with different parameter cavities were selected as the research object, and experiments on remote detection using Laser Doppler Vibrometry were conducted.

View Article and Find Full Text PDF

Patients at high risk of deep vein thrombosis are recommended to undergo lower-extremity ultrasonography to screen for pulmonary embolism (PE); however, there are few reports on whether this can effectively reduce the occurrence of fatal pulmonary embolism (FPE). This study aimed to assess the risk factors associated with PE and to investigate whether perioperative ultrasound screening of lower extremity veins in orthopedic patients can effectively reduce the incidence of FPE. We enrolled 137 patients with PE who underwent orthopedic surgery between 2013 and 2020.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!