Background: We used axial loading computed tomography (AL CT) to evaluate preoperative and postoperative talocrural joints of patients who underwent supramalleolar osteotomy (SMO) to treat varus ankle osteoarthritis.

Methods: We performed retrospective analyses of 16 patients (18 feet) who underwent SMO including fibular osteotomy. Radiographic assessment was performed with weightbearing radiographs and AL CT. Clinical outcomes were assessed based on American Orthopedic Foot & Ankle Society (AOFAS) scale, visual analog scale (VAS) for pain, and Foot and Ankle Ability Measure (FAAM).

Results: The mean 2-year follow-up tibial-ankle surface angle, talar tilt angle, Takakura stage, and tibial-lateral surface angle were all significantly different relative to preoperative parameters (P<.05). The mean 6-month follow-up talus rotation ratio was significantly corrected compared to the preoperative value (P=.001). The mean 2-year follow-up AOFAS, VAS at gait, and FAAM scores were all significantly improved relative to preoperative measurements (P=.001).

Conclusions: Abnormal internal rotation of the talus in mild to moderate varus ankle osteoarthritis found on AL CT was significantly corrected after SMO.

Level Of Evidence: Therapeutic Level IV.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fas.2020.04.006DOI Listing

Publication Analysis

Top Keywords

axial loading
8
loading computed
8
computed tomography
8
varus ankle
8
supramalleolar osteotomy
8
foot ankle
8
surface angle
8
perioperative axial
4
tomography findings
4
findings varus
4

Similar Publications

Relative abundance of atropisomer pairs in metolachlor metabolites, MESA and MOXA, vary with slope and hydric soils in subwatersheds of the Choptank River watershed, Maryland.

Sci Total Environ

January 2025

US Department of Agriculture, Agriculture Research Service, Hydrology and Remote Sensing Laboratory, Beltsville, MD, United States of America.

Metolachlor is the most heavily used member of acetanilide herbicides, which are noted for forming highly soluble metabolites in root zone soils soon after field application. The two primary metabolites of metolachlor, metolachlor ethane sulfonic acid (MESA) and metolachlor oxanilic acid (MOXA), retain the same chiral chemistry as their source and are important tracers of nitrate loading from agricultural cropland. New analytical methods for separating the isomers of MESA and MOXA, enable studies assessing changes in the abundance of atropisomer pairs of the carbon chiral enantiomers in environmental samples.

View Article and Find Full Text PDF

Introduction: Reconstruction for various regions of the foot and ankle in pediatric patients remains a challenging topic. This study presents the circumflex scapular artery perforator (CSAP) flap and its surgical refinements for addressing soft tissue defects in various regions of the foot and ankle in pediatrics.

Patients And Methods: Forty-seven patients underwent CSAP flap and its surgical refinements for the reconstruction of foot and ankle defects from 2010 to 2022.

View Article and Find Full Text PDF

Load-bearing capacity of an experimental dental implant made of Nb-1Zr.

J Mater Sci Mater Med

January 2025

Clinic of Prosthetic Dentistry and Biomedical Materials Research, Hannover Medical School, Hannover, Germany.

Although implants have undergone a remarkable development over the past decades, modern implants still show complications that make the improvement of materials necessary. The presented study investigates the load-bearing capacity of an experimental dental implant made of a niobium alloy (Nb1Zr) compared to identical implants made of Ti6Al4V using chewing simulation for artificial aging. Eight implants each with an experimental design were manufactured from Nb1Zr and Ti6Al4V.

View Article and Find Full Text PDF

Background And Objective: A safe working trajectory is mandatory for spinal pathologies, especially in the midline, anterior to the spinal cord. For thoracic cerebrospinal fluid (CSF) leaks, we developed a minimally invasive keyhole fenestration. This study investigates the necessary bone removal for sufficient exposure of different leak types particularly regarding weight-bearing structures.

View Article and Find Full Text PDF

Purpose: This study aims to evaluate the effects of taper angle and the number of insertion-removal cycles on the retention force of 4 mol% yttria partially stabilized zirconia (4Y-PSZ) double crowns over time.

Materials And Methods: Primary and secondary crowns were fabricated using 4Y-PSZ with taper angles of 2°, 4°, and 6° (n=15). Retention force during crown removal was measured after applying 50-N and 100-N loads.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!