Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: Treatment of acromioclavicular joint (ACJ) dislocation is not encoded uniquely. Type I and II injuries are usually treated conservatively, while types IV, V and VI surgically. Controversy still exists over the treatment of type III injuries. In the operative approach, there is no agreement on the best surgical technique. Our purpose is to compare the mini-open and arthroscopic approach focusing on the evaluation of the anatomical precision of the coracoid drilling.
Methods: This is a controlled laboratory study. Ten fresh-frozen cadaveric shoulders were randomly assigned to the two techniques in order to compare them. We performed essential surgical gestures to drill the tunnel using MINAR® System (mini-open) and Dog-Bone® (ARTHREX, arthroscopic). The anatomical specimens were then subjected to CT-scan investigation. We statistically evaluated the precision of these two techniques analyzing DICOM files using two parameters. Parameter 1 evaluates the tunnel entry area on the superior side of the coracoid. Parameter 2 describes the orientation of the tunnel.
Results: There are no statistically significant differences (95% confidence level) between arthroscopic and mini-open approach about the precision in the location of the coracoid hole, regarding the entry area (p = 1.00) and the orientation (p = 0.196).
Conclusion: The evidences collected enable the orthopedic surgeon to choose equally between the two techniques in the treatment of AC joint dislocation toward precision.