This review article combines the reports on the biophysical effects in ultrasonography and provides the rationale behind the mechanical index (MI) and thermal index (TI) complying with the Output Display Standard (ODS). Safe ultrasonic doses are determined according to specific rules, and the screen displays the associated quantities MI and TI. The introduced indices MI and TI take into account the physical mechanism of interaction between ultrasounds and biological tissue, which depends on the temporal and spatial parameters of the acoustic field generated by ultrasound transducers. The predicted temperature increase is determined using three different tissue models: homogeneous, layered and bone/tissue interface.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11152/mu-2372 | DOI Listing |
Int J Surg
December 2024
Department of Surgery, Sapienza University of Rome, Rome.
Background: One of the most important surgical steps during thyroidectomy is the safe ligation of vessels. In fact, it is crucial to avoid postoperative bleeding and nerves' injury. The "clamp and tie" technique was first introduced in the 19th century.
View Article and Find Full Text PDFJ Neurosurg Case Lessons
January 2025
Division of Neurosurgery, Department of Surgery, Hospital Ignacio Pirovano, Buenos Aires, Argentina.
Background: Resection of calcified meningiomas in the ventral thoracic spinal canal remains a formidable surgical challenge despite advances in technology and refined microsurgical techniques. These tumors, which account for a small percentage of spinal meningiomas, are characterized by their hardness, complicating safe resection and often resulting in worse outcomes than their noncalcified counterparts.
Observations: The authors present the case of a 68-year-old woman with a ventrally located ossified meningioma at the T9-10 level, successfully treated via a posterolateral transpedicular approach.
JACC Cardiovasc Interv
December 2024
Department for Angiology, Brandenburg Medical School Theodor Fontane, Campus Clinic Brandenburg, Center for Internal Medicine I, Berlin, Germany; Department of Angiology, Sankt-Gertrauden-Krankenhaus, Berlin, Germany.
Background: Several randomized clinical trials have shown that the composite endpoint of death, stroke, and myocardial infarction (MI) is equivalent between carotid artery stenting and carotid endarterectomy. However, the risk of minor stroke has been consistently higher with carotid artery stenting.
Objectives: The authors sought to evaluate the safety and effectiveness of a novel carotid stent system comprised of a stent, an adjustable integrated embolic filter and a postdilation balloon, in patients at elevated risk for adverse events from carotid endarterectomy.
Food Addit Contam Part A Chem Anal Control Expo Risk Assess
January 2025
Jiangyin Food Safety Testing Center, Jiangyin, P. R. China.
Illegal additives such as oxyphenisatine and its esters are prevalent in the slimming food industry, necessitating a robust analytical method for their detection. This study presents a novel UPLC-MS/MS method for the rapid and accurate quantification of total oxyphenisatine levels in fermented green plum, following hydrolysis of its esters. An efficient ultrasonic extraction with a methanol and 0.
View Article and Find Full Text PDFTransl Vis Sci Technol
January 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Purpose: The purpose of this study was to characterize whether pulsed ultrasound (PUS) affects transscleral drug delivery.
Methods: Fluorescein sodium (NaF, 376 Da) and fluorescein isothiocyanate-conjugated dextran 40 (FD-40, 40 kDa) were used as model drugs. Human sclera grafts were placed in modified Franz diffusion cells and were treated by PUS (1 megahertz [MHz], 0.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!