Background: The potential advantages of hydroxyapatite (HA)-coated cementless total knee arthroplasty (TKA) implants are bone stock preservation and biological fixation. Studies comparing the outcomes of HA-coated cementless, non HA-coated cementless (uncemented) and cemented TKA implants reported contradictory data. Our aim was to provide a comparison of the effects of HA coating of tibial stem on the stability and functionality of TKA implants.

Methods: A systematic literature search was performed using MEDLINE, Scopus, EMBASE and the CENTRAL databases up to May 31st, 2019. The primary outcome was Maximum Total Point Motion (MTPM) of the tibial stem. This parameter is determined by radiosterometric analysis and refers to the migration pattern of the prosthesis stems. The clinical outcomes of the implanted joints were evaluated by the Knee Society Knee Score (KSS) and the Knee Society Function Score (KFS). Weighted mean difference (WMD) with 95% confidence interval (CI) were calculated with the random-effects model.

Results: Altogether, 11 randomized controlled trials (RCTs) with 902 patients for primary TKA implants were included. There was a statistically significant difference in the MTPM values with the use of HA-coated and uncoated uncemented implants (WMD = +0.28, CI: +0.01 to +0.56, P<0.001). However, HA-coated stems showed significantly higher migration when compared with the cemented prostheses (WMD = -0.29, CI: -0.41 to -0.16, P<0.001). The KSS values of HA-coated implants were significantly higher than those for the uncemented implants; moreover, KSS and KFS outcome scores were statistically not different between the HA-coated and cemented prosthesis cases.

Conclusion: HA-coating yields better stability than other, uncemented prostheses. More importantly, the HA-coating is not outperformed by cemented prosthesis in providing good functional outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7217427PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0232378PLOS

Publication Analysis

Top Keywords

ha-coated cementless
12
tka implants
12
total knee
8
knee arthroplasty
8
randomized controlled
8
controlled trials
8
tibial stem
8
knee society
8
knee
5
hydroxyapatite-coated implants
4

Similar Publications

Introduction: We aimed to compare periprosthetic femoral bone remodeling after cementless total hip arthroplasty (THA) using a short-tapered wedge stem and a fully hydroxyapatite (HA)-coated stem.

Materials And Methods: In this retrospective study, 24 primary cementless THA procedures with short-tapered wedge stem and 24 using a fully HA-coated stem were performed. The follow-up duration was 2 years for both groups.

View Article and Find Full Text PDF

Slipped capital femoral epiphysis after tumor prosthesis implantation in a patient receiving chemotherapy.

Jt Dis Relat Surg

February 2024

Universitätsklinikum Essen, Die Klinik für Tumororthopädie und Sarkomchirurgie Hufelandstraße 55, 45147 Essen, Germany.

While the usual etiology of slipped capital femoral epiphysis (SCFE) is idiopathic, there are many other factors that increase the predisposition to slippage. Chemotherapy can be one of them. In this article, we report a rare case of acute SCFE after tumor prosthesis implantation in a patient who received chemotherapy.

View Article and Find Full Text PDF

Background: Intraoperative femoral fractures are more common in cementless bipolar hip arthroplasty (BHA) for displaced femoral neck fractures than they are in cemented BHA and remain one of the major concerns. This study aimed to investigate the risk factors for intraoperative femoral fractures in cementless BHA.

Methods: The study included 1,392 patients who underwent cementless BHA for displaced femoral neck fractures from January 2015 to December 2019 in 14 hospitals of the Trauma Research Group.

View Article and Find Full Text PDF

Aims: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface.

Methods: Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating. All components were used in combination with a cemented Exeter V40 femoral stem.

View Article and Find Full Text PDF

Short stem, uncemented femoral implants for hip arthroplasty are bone conserving achieving stability through initial metaphyseal press-fit and biological fixation. This study aimed to evaluate the survivorship, mid-term function and health related quality of life outcomes in patients who have undergone total hip arthroplasty (THA) with a fully hydroxyapatite coated straight short stem femoral component with up to 5 years follow-up. 668 patients were recruited to a multicentre study investigating the performance of the cementless Furlong Evolution stem for THA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!