[Surgical Treatment of Clavicle Midshaft Fractures - Prospective Randomized Trial].

Acta Chir Orthop Traumatol Cech

Katedra vojenské chirurgie, Fakulta vojenského zdravotnictví, Univerzita obrany v Brně, Hradec Králové.

Published: June 2020

PURPOSE OF THE STUDY Comparison of the outcomes of clavicle midshaft fractures using two different surgical techniques, namely intramedullar osteosynthesis using elastic stable intramedullary nailing (ESIN) with medial cap and extramedullar plate osteosynthesis. MATERIAL AND METHODS The prospective randomized trial was conducted at the Department of Trauma Surgery of the Department of Surgery of the University Hospital Hradec Králové in the Czech Republic at the Level I Trauma Center between 2014 and 2018 and compared two types of osteosynthesis of clavicle midshaft fractures. 60 patients were enrolled in the study and were randomly assigned to one of the two groups. In Group 1, the participants were treated by ESIN and in Group 2 by plate osteosynthesis. The operative technique was chosen by the sealed envelope method. According to the randomization list created by a specialised statistical company, every envelope was marked with a unique number and contained the intramedullar "IM", or the extramedullar "EM" sign. RESULTS The observation of statistical parameters by unpaired t test detected significantly different results: a shorter incision using ESIN osteosynthesis (median = 2.9 cm) compared with plate osteosynthesis (median 14 cm, p < 0.001), longer X-ray exposure using ESIN (median = 325 s) compared with plate osteosynthesis (median = 16.5 s, p < 0.001) and radiation dose using ESIN (median = 996 cGy/cm2) compared with plate osteosynthesis (median = 4 cGy/cm2, p < 0.001). The difference in other parameters such as operative time, in-patient length of stay and duration of rehabilitation was not statistically significant. The time to clavicle fracture repair was comparable in both the surgical arms, i.e. approximately 3 months. Also, the duration of incapacity for work was not statistically different. Functional Constant Shoulder Score at a one-year followup is comparable in both the two arms (p = 0.268). The Dunn s method necessitated a longer operative time when treating multifragmental midshaft clavicle fracture by the ESIN compared to simple fractures. No statistically significant difference was detected in the operative time of different procedures and in the number of bone fragments. The functional outcome was excellent in 25 patients (83%) in each method. DISCUSSION Most midshaft clavicle fractures are still treated non-operatively with good outcomes. The indication for surgical treatment is the dislocation of fragments greater than the width of the clavicle bone, the shortening of fragments greater than 2 cm and the angulation of more than 30°. Patient after operative treatment profits from bone healing by absolute or relative stability. In recent years, new intramedullar techniques other than open plate reduction and fixation have emerged. For example, elastic stable intramedullary titan nailing. Both the methods are full-fledged without functional differences in longterm follow-up. CONCLUSIONS We consider the intramedullar osteosynthesis to be the most appropriate surgical approach for simple midshaft spiral, oblique and transverse clavicle fractures and also wedge oblique fractures. Plate osteosynthesis is useful for all types of fractures. No statistically significant difference in the rate of bone healing was observed after intramedullar or extramedullar ostesynthesis, but multifragmentary fractures healed faster when plate osteosynthesis was used. The determining factor for the received radiation dose is solely the surgical method, not the type of fracture. There is a statistically significant difference in shorter X-ray exposure and lower received radiation dose in plate fixation and reduction. The complication rate is comparable in both the methods. Key words: elastic stable intramedullary nailing, midshaft clavicle fracture, ESIN, TEN, titan elastic nail, clavicle plate osteosynthesis, 3.5 LCP clavicular plate, indication for midshaft fracture treatment.

Download full-text PDF

Source

Publication Analysis

Top Keywords

plate osteosynthesis
32
osteosynthesis median
16
clavicle midshaft
12
midshaft fractures
12
osteosynthesis
12
elastic stable
12
stable intramedullary
12
compared plate
12
radiation dose
12
operative time
12

Similar Publications

Background: Total ankle replacement (TAR) has evolved in the last decade from a procedure rife with complication and failure to a promising alternative to arthrodesis. The ability to maintain ankle joint range of motion is showing great promise in patient-reported outcomes, postsurgical pain, as well as long-term sequalae of joint fusion. Although TAR can be performed via either an anterior or lateral approach both with their own sets of benefits and potential complications, the consensus seems to be that one is no better than the other when performed by high-volume surgeons.

View Article and Find Full Text PDF

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Purpose: To investigate the factors that prolonged the operative duration (OD) in patients who underwent single-stage locked intramedullary nailing of their multiple concurrent long-bone fractures (LBFs) using Surgical Implant Generation Network (SIGN) nails.

Methods: Forty-nine patients who fulfilled the inclusion criteria were enrolled prospectively over 8½ years. Data collected included age, sex, injury mechanism and severity, fracture characteristics, nail types and diameter, OD, fracture-to-fixation time, length of hospital stay (LOS), functional outcomes and complications.

View Article and Find Full Text PDF

Background: Low-profile double plating seems a viable alternative to conventional single plating for fixation of midshaft clavicle fractures. This study aims to compare the two techniques regarding healing, complications, and removal rate.

Methods: This retrospective cohort study included all patients >16 years that underwent plate fixation for midshaft clavicle fractures between 2020 and 2022 at one trauma-center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?