The phase correction necessary for transcranial ultrasound therapy requires numerical simulation to noninvasively assess the phase shift induced by the skull bone. Ideally, the numerical simulations need to be fast enough for clinical implementation in a brain therapy protocol and to provide accurate estimation of the phase shift to optimize the refocusing through the skull. In this article, we experimentally performed transcranial ultrasound focusing at 900 kHz on N = 5 human skulls. To reduce the computation time, we propose here to perform the numerical simulation at 450 kHz and use the corresponding phase shifts experimentally at 900 kHz. We demonstrate that a 450-kHz simulation restores 94.2% of the pressure when compared with a simulation performed at 900 kHz and 85.0% of the gold standard pressure obtained by an invasive time reversal procedure based on the signal recorded by a hydrophone placed at the target. From a 900- to 450-kHz simulation, the grid size is divided by 8, and the computation time is divided by 10.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2020.2993718DOI Listing

Publication Analysis

Top Keywords

900 khz
12
transcranial ultrasound
8
numerical simulation
8
phase shift
8
computation time
8
450-khz simulation
8
simulation
5
computationally efficient
4
efficient transcranial
4
transcranial ultrasonic
4

Similar Publications

Adding value to food by-products, such as pumpkin seeds, is an important strategy for the complete utilization of plant foods and advancing sustainability goals. This study aimed to maximize the production of bioactive peptides from pumpkin seed protein (PSP) by combining ultrasonic (US) pretreatment (40 kHz, 23.8 W/L) with enzymatic hydrolysis.

View Article and Find Full Text PDF

Distributed feedback lasers, which feature rapid wavelength tunability, are not presently available in the yellow and orange spectral regions, impeding spectroscopic studies of short-lived species that absorb light in this range. To meet this need, a rapidly tunable laser system was constructed, characterized, and demonstrated for measurements of the NH radical at 597.4 nm.

View Article and Find Full Text PDF

Organic photodetectors (OPDs) with a near-infrared (NIR) response beyond 900 nm are intriguing electronics for various applications. It is challenging to develop NIR OPDs with high sensitivity and fast response. Herein, the acceptor materials of OPDs are tuned to extend detection to ≈1100 nm with improved sensitivity.

View Article and Find Full Text PDF

Active acoustic metamaterials (AAMM) have garnered special attention because of their potential as multi-function devices. In this direction, the present article demonstrates a novel AAMM that can be programmed as a multi-functional Active Acoustic Meta-device (AAMD) that can switch functionalities between Acoustic Switch (AS), Acoustic Lens (AL), and Acoustic Barrier (AB). Functionality: AL corresponds to the wave vector space, and AS and AB correspond to the frequency space of the proposed AAMM.

View Article and Find Full Text PDF

Ultrathin nanocapacitor assembled via atomic layer deposition.

Nanotechnology

September 2024

Universidad Nacional Autónoma de México Centro de Nanociencias y Nanotecnología, Km 107 Carretera Tijuana-Ensenada, Ensenada, B.C., C.P. 22800, Mexico, Ensenada, Baja California, 22800, MEXICO.

We fabricated ultrathin metal - oxide - semiconductor (MOS) nanocapacitors using atomic layer deposition. The capacitors consist of a bilayer of Al2O3 and Y2O3 with a total thickness of ~10 nm, deposited on silicon substrate. The presence of the two materials, each slab being ~5 nm thick and uniform over a large area, was confirmed with Transmission Electron Microscopy and X-ray photoelectron spectroscopy (XPS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!