Evaluation of LIBRA Software for Fully Automated Mammographic Density Assessment in Breast Cancer Risk Prediction.

Radiology

From the Department of Radiology, University of Pennsylvania, Philadelphia, Pa (A.G., E.F.C., D.K.); Department of Radiology, University of Minnesota, Minneapolis, Minn (C.D.K.); Departments of Health Sciences Research (C.G.S., M.R.J., A.D.N., S.J.W., C.M.V.), Diagnostic Radiology (K.R.B., C.B.H.), Information Technology (F.F.W.), Mayo Clinic, 200 First St SW, Rochester, MN 55905; and Department of Medicine and Epidemiology, University of California, San Francisco, San Francisco, Calif (K.K.).

Published: July 2020

Background The associations of density measures from the publicly available Laboratory for Individualized Breast Radiodensity Assessment (LIBRA) software with breast cancer have primarily focused on estimates from the contralateral breast at the time of diagnosis. Purpose To evaluate LIBRA measures on mammograms obtained before breast cancer diagnosis and compare their performance to established density measures. Materials and Methods For this retrospective case-control study, full-field digital mammograms in for-processing (raw) and for-presentation (processed) formats were obtained (March 2008 to December 2011) in women who developed breast cancer an average of 2 years later and in age-matched control patients. LIBRA measures included absolute dense area and area percent density (PD) from both image formats. For comparison, dense area and PD were assessed by using the research software (Cumulus), and volumetric PD (VPD) and absolute dense volume were estimated with a commercially available software (Volpara). Density measures were compared by using Spearman correlation coefficients (), and conditional logistic regression (odds ratios [ORs] and 95% confidence intervals [CIs]) was performed to examine the associations of density measures with breast cancer by adjusting for age and body mass index. Results Evaluated were 437 women diagnosed with breast cancer (median age, 62 years ± 17 [standard deviation]) and 1225 matched control patients (median age, 61 years ± 16). LIBRA PD showed strong correlations with Cumulus PD ( = 0.77-0.84) and Volpara VPD ( = 0.85-0.90) ( < .001 for both). For LIBRA, the strongest breast cancer association was observed for PD from processed images (OR, 1.3; 95% CI: 1.1, 1.5), although the PD association from raw images was not significantly different (OR, 1.2; 95% CI: 1.1, 1.4; = .25). Slightly stronger breast cancer associations were seen for Cumulus PD (OR, 1.5; 95% CI: 1.3, 1.8; processed images; = .01) and Volpara VPD (OR, 1.4; 95% CI: 1.2, 1.7; raw images; = .004) compared with LIBRA measures. Conclusion Automated density measures provided by the Laboratory for Individualized Breast Radiodensity Assessment from raw and processed mammograms correlated with established area and volumetric density measures and showed comparable breast cancer associations. © RSNA, 2020

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7325699PMC
http://dx.doi.org/10.1148/radiol.2020192509DOI Listing

Publication Analysis

Top Keywords

breast cancer
36
density measures
24
breast
12
libra measures
12
cancer
9
measures
9
libra software
8
density
8
associations density
8
laboratory individualized
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!