Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw.

Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications.

Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale.

Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of peri-implant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7192825PMC
http://dx.doi.org/10.5051/jpis.2020.50.2.97DOI Listing

Publication Analysis

Top Keywords

anterior posterior
20
ndis anterior
16
clinical radiographic
8
jaw years
8
fixed prostheses
8
posterior region
8
patient satisfaction
8
anterior
6
posterior
6
ndis
6

Similar Publications

Hypereosinophilic syndrome (HES) is traditionally described as chronic peripheral eosinophilia with involvement of various organs and systems, including the heart and nervous system. In this report, we describe cardiac involvement and border zone stroke in a patient with idiopathic HES. A 37-year-old woman presented with sudden right-sided weakness and slurred speech, which began four days before admission, accompanied by palpitations, retrosternal exertional chest discomfort, dry cough, and progressive shortness of breath over approximately two months.

View Article and Find Full Text PDF

Does Scapular and Thoracic Morphology Affect Latarjet Alpha Angle?

J Clin Med

January 2025

Department of Orthopedics and Traumatology, Faculty of Medicine, Istanbul University, Istanbul 34093, Turkey.

This study aimed to determine the relationship between alpha angle (the angle between the screws and the glenoid) and thoracic diameters in patients undergoing the Latarjet procedure. Defining the relationship between thoracic morphology and alpha angle is aimed at filling the gap in the literature and improving surgical outcomes. This retrospective study analyzed 74 patients who underwent the Latarjet procedure for recurrent anterior shoulder instability between 2022 and 2024.

View Article and Find Full Text PDF

The aim of this retrospective study was to compare corneal parameters and compliance using a Pentacam HR-Scheimpflug (Pentacam HR) and a swept-source OCT Casia (Casia) in keratoconus (KC) patients post penetrating keratoplasty (PKP) and KC patients without PKP, as well as a control group. Pachymetry measurements were also analyzed using a spectral domain OCT Solix (OCT Solix), Pentacam HR, and Casia. The study included 71 patients (136 keratoconic eyes; group A), 86 eyes with KC post-PKP (group B), 50 eyes with KC without PKP (group C), and 52 control participants (104 eyes).

View Article and Find Full Text PDF

Intracranial atherosclerosis (ICAS) is a major cause of ischemic stroke, disproportionately affecting populations with significant vascular risk factors. Although ICAS imposes a considerable health burden, research on this condition in Central Asia remains scarce, especially among the Kazakh population. This study analyzes demographic characteristics, treatment outcomes, and procedural challenges associated with ICAS in 216 patients treated at a single institution.

View Article and Find Full Text PDF

Validity and Reliability of Kinovea for Pelvic Kinematic Measurement in Standing Position and in Sitting Position with 45° of Hip Flexion.

Sensors (Basel)

January 2025

Unidad de Investigación en Fisioterapia, Spin off Centro Clínico OMT-E Fisioterapia SLP, Universidad de Zaragoza, Domingo Miral s/n, 50009 Zaragoza, Spain.

The anatomy of the pelvis may obscure differences in pelvic tilt, potentially underestimating its correlation with clinical measures. Measuring the total sagittal range of pelvic movement can serve as a reliable indicator of pelvic function. This study assessed the inter- and intra-examiner reliability of the Kinovea version 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!