A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy and Safety of Robot-Assisted Drilling Decompression for Osteonecrosis of the Femoral Head. | LitMetric

AI Article Synopsis

  • The study aimed to evaluate the safety and effectiveness of robot-assisted surgery compared to traditional methods for treating femoral head necrosis in 63 patients.
  • Results showed that the robot-assisted group had significantly shorter incision lengths, shorter operation times, reduced intraoperative blood loss, and fewer fluoroscopy uses, indicating a less invasive and more efficient procedure.
  • Postoperative recovery outcomes, measured by Harris scores, were comparable between both groups but slightly higher in the robot-assisted group, suggesting it may offer better recovery potential.

Article Abstract

Objective: To investigate the safety and superiority of robot-assisted femoral head drilling decompression in the treatment of femoral head necrosis.

Methods: A total of 63 patients who underwent borehole decompression of the femoral head in our hospital from January 2016 to March 2019 were recruited. Patients were divided into two groups for comparison according to surgical methods. In the robot-assisted surgery group, there were 30 cases with 41 femoral heads. The conventional group had 33 cases and 46 femoral heads. All patients signed the consent form before the operation. The follow-up time was 6 months. The incision lengths, operation times, intraoperative blood loss, intraoperative fluoroscopies, guide needle punctures, postoperative Harris scores, and postoperative complications of the two groups were compared.

Results: The incision length of the robot surgery group was 5.16 ± 0.41 cm, while that of the traditional surgery group was 7.42 ± 0.50 cm. The operation time of the robot surgery group was 46.99 ± 4.94 min, while that of the traditional surgery group was 55.01 ± 6.19 min. The fluoroscopy frequency of the robot surgery group was 10.50 ± 1.78 times, while that of the traditional surgery group was 17.91 ± 2.20 times. The intraoperative blood loss in the robotic surgery group was 20.62 ± 2.52 mL, while that in the conventional surgery group was 52.72 ± 3.39 mL. In the robot operation group, each femoral head guide needle was punctured three times, and the puncture was successful one time. The number of guided needle punctures in the traditional group was 8.02 ± 1.73. The difference between the two groups was statistically significant (P < 0.05). The Harris score was 69.53 ± 7.51 in the robot surgery group and 68.38 ± 7.26 in the traditional surgery group one month after surgery, 78.52 ± 6.49 in the robot surgery group and 76.41 ± 7.95 in the traditional surgery group three months after surgery, and 83.32 ± 8.62 in the robot surgery group and 81.74 ± 6.20 in the traditional surgery group six months after surgery. There was no significant difference between the two groups (P > 0.05). In the traditional group, there was one case of incision infection and one case of femoral head collapse during follow-up. In the robot group, there were no complications, such as incision infection and deep vein thrombosis. No collapse of the femoral head was found in the robot group during follow-up.

Conclusion: The positioning system of the orthopaedic robot is an ideal method for the treatment of femoral head necrosis. This method has the advantages of simple operation, accurate drilling, a short operation time, less surgical trauma, less radioactivity, and good recovery of hip joint function.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7307221PMC
http://dx.doi.org/10.1111/os.12678DOI Listing

Publication Analysis

Top Keywords

surgery group
36
femoral head
32
group
15
robot surgery
12
traditional surgery
12
femoral
10
surgery
9
drilling decompression
8
head
8
treatment femoral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!