A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of suturing performance in general surgery and ocular microsurgery by combining computer vision-based software and distributed fiber optic strain sensors: a proof-of-concept. | LitMetric

Purpose: Improper suturing may cause an inadequate wound healing process and wound dehiscence as well as infection and even graft rejection in case of corneal transplantation. Hence, training surgeons in correct suturing procedures and objectively assessing their surgical skills is desirable.

Methods: Two complementary methods for assessment of suturing skills in two medical fields (general surgery and ocular microsurgery) were demonstrated. Suturing quality is assessed by computer vision software. Evaluation of stitching flow of operation is based on measuring strain induced in an optical fiber that is placed in proximity to the wound and parallel thereto and is pressed and passed by wound stitches.

Results: Our software generated a score for suturing outcome in both general surgery and ocular microsurgery when the stitching was done on a patch. Every trainee received a score in the range 0-100 that describes his/her performance. Strain values were recognized when using a patch in general surgery and a rubber patch in ocular microsurgery, but were less distinct in (disqualified) human cornea.

Conclusions: We proved a concept of an objective scoring method (based on various image processing algorithms) for assessment of suturing performance. It was also shown that fiber optic strain sensors are sensitive to the flow of stitching operation on a patch but are less sensitive to the flow of stitching operation on a human cornea. By combining these two methods, we can comprehensively evaluate the suturing performance objectively.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-020-02187-yDOI Listing

Publication Analysis

Top Keywords

general surgery
16
ocular microsurgery
16
suturing performance
12
surgery ocular
12
fiber optic
8
optic strain
8
strain sensors
8
assessment suturing
8
sensitive flow
8
flow stitching
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!