A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A fluorescent amplification strategy for high-sensitive detection of 17 β-estradiol based on EXPAR and HCR. | LitMetric

A fluorescent amplification strategy for high-sensitive detection of 17 β-estradiol based on EXPAR and HCR.

Anal Chim Acta

Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Institute of Environmental and Operational Medicine, Academy of Military Medical Science, Academy of Military Science, Tianjin, 300050, PR China. Electronic address:

Published: June 2020

Environmental endocrine disruptors in the environment and food, especially 17 β-estradiol (E2), are important factors affecting the growth and development of organisms. In this research, we constructed a fluorescence strategy for two-step amplification that combined two currently popular methods, exponential amplification reaction (EXPAR) and hybridization chain reaction (HCR). E2 competed with the complementary DNA (cDNA) to bind the aptamer modified on the magnetic beads. The free complementary strand in the supernatant was used as a trigger sequence to activate EXPAR, producing a large amount of short single-stranded DNA (ssDNA). The amplified ssDNA can trigger the second HCR amplification, producing many long double-stranded DNA (dsDNA) analogues. According to the principle of fluorescence resonance energy transfer, the carboxyfluorescein (FAM) signals in H1 and H2 hairpins were quenched by black hole quencher (BHQ-1). After the addition of E2 and initiation of amplification, the initially quenched fluorescent signal would be restored. This strategy with a detection limit of 0.37 pg mL (S/N = 3) showed a good linear relationship in the range of 0.4-800 pg mL. In addition, the recovery rates of the method for milk and water samples were 98.55%-116.95% and 92.32%-107.00%, respectively. This is the first report of the combined detection of EXPAR and HCR, providing a reference for rapid and highly sensitive detection using multiple isothermal amplification methods.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2020.04.010DOI Listing

Publication Analysis

Top Keywords

expar hcr
8
amplification
5
fluorescent amplification
4
amplification strategy
4
strategy high-sensitive
4
detection
4
high-sensitive detection
4
detection β-estradiol
4
β-estradiol based
4
expar
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!