A Comparison of Mtwo and RaCe Rotary Instruments in the Preparation of Curved Canals.

J Contemp Dent Pract

Department of Endodontic, The Chief of Endodontic Catheder, University "Gabriele D'Annunzio" Chiety, Italy.

Published: February 2020

Aim: The aim of this study was to compare the effectiveness of Mtwo and RaCe rotary instruments in cleaning and shaping root canals curvature.

Materials And Methods: The present study was conducted on 160 simulated canals in resin blocks with an angle curvature of 15°-30°. These 160 simulated canals were divided into two groups, where each group consisted of 80 blocks. In the first group, the canals were prepared using Mtwo rotary system (VDW, Munich, Germany). In the second group, the canals were prepared using RaCe instruments (La Chaux-De-Fonds, Switzerland). The data were recorded using SPSS version 23 software (Microsoft, IL, USA).

Results: The results obtained by using the Mtwo rotary instruments showed that these instruments were able to clean and shape in the right-to-left motion curved canals, at different levels, without any deviation and in perfect symmetry, with a value = 0.000. The data showed that greater the depth of the root canal, greater the deviations of the RaCe rotary instruments. These deviations occurred in three levels, which are the following: S2 ( = 0.004), S3 ( = 0.007), and S4 ( = 0.009). The Mtwo files can go deeper and create a greater angle in S4 level (21°-28°) compared to RaCe instruments with an angle equal to 19°-24°.

Conclusion: The present study noted a clinical significant difference between Mtwo rotary instruments and RaCe rotary files used for the canal preparation and indicated that Mtwo instruments are a better choice for the curved canals.

Clinical Significance: There are a large number of procedures and instruments used in the preparation of the root canal. Mtwo and RaCe rotary files were the instruments taken under comparison, in order to determine which of them would perform better.

Download full-text PDF

Source

Publication Analysis

Top Keywords

race rotary
20
rotary instruments
20
mtwo race
12
mtwo rotary
12
instruments
11
rotary
8
instruments preparation
8
curved canals
8
160 simulated
8
simulated canals
8

Similar Publications

This study aimed to evaluate the efficacy of the orifice-level passive ultrasonic activation (OL-PUA) technique in removing debris from the mesial root canals of mandibular molars, besides comparing it with other approaches, including manual dynamic agitation (MDA), EndoActivator, and laser-activated irrigation (LAI). Ninety mesial roots of mandibular molars were prepared up to 25.06 using the Race rotary system, filled with 3% sodium hypochlorite (NaOCl), and then they were randomly assigned to 5 groups (n=15) based on the activation protocol: MDA, EndoActivator, OL-PUA, LAI (using a diode laser), and needle irrigation (no activation).

View Article and Find Full Text PDF

Introduction: In this study, the cleaning ability of a stainless-steel rotary instrument called Gentlefile, was compared with three nickel-titanium rotary instruments.

Materials And Methods: In this study, forty mandibular single-rooted premolars were randomly assorted into four groups: Gentlefile, ProTper Universal, RaCe files, and XP-Endo Finisher/ProTaper Universal system (=10). Final instrumentation was done using the aforementioned files with 5.

View Article and Find Full Text PDF

Background: Metabolic dysfunction associated steatotic liver disease (MASLD) is associated with increased cardiovascular disease (CVD) risk in persons with HIV (PWH). The lipidomic and metabolomic alterations contributing to this risk are poorly understood. We aimed to characterize the advanced lipoprotein and targeted metabolomic profiles in PWH and assess if the presence and severity of MASLD influence these profiles.

View Article and Find Full Text PDF

The amount of apically extruded debris following glide-path preparation of mesial root of 120 freshly extracted human mandibular molar teeth using Senseus ProFinder files, PathFile, G-Files, Scout-RaCe files, HyFlex glidepath files and V glide-path two file system is of interest. The Eppendorf tubes were used as test equipment for collecting debris and the average weight of the debris was measured using an electronic micro-balancing system. It was observed that regardless of the file system utilized, debris was expelled from the apex.

View Article and Find Full Text PDF

Introduction: This study aimed to compare a new multicolored rotary system with four heat-treated rotary instruments using the multimethod approach.

Methods: Three-hundred instruments of RCS Rainbow, Rotate, RaCe EVO, OneCurve, and ProTaper Ultimate systems were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy, and mechanical performance (cyclic fatigue, torsional resistance, bending and buckling resistance, and cutting ability). Unprepared surfaces after canal preparation of maxillary molars were evaluated using micro-computed tomography.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!