The effects of wet wipe pollution on the Asian clam, Corbicula fluminea (Mollusca: Bivalvia) in the River Thames, London.

Environ Pollut

Department of Biological Sciences, School of Life Sciences and the Environment, Royal Holloway University of London, Egham, Surrey, TW20 0EX, UK.

Published: September 2020

The aim of the present study was to evaluate "flushable" and "non-flushable" wet wipes as a source of plastic pollution in the River Thames at Hammersmith, London and the impacts they have on the invasive Asian clam, Corbicula fluminea, in this watercourse. Surveys were conducted to assess whether the density of wet wipes along the foreshore upstream of Hammersmith Bridge affected the distribution of C. fluminea. High densities of wet wipes were associated with low numbers of clams and vice versa. The maximum wet wipe density recorded was 143 wipes m and maximum clam density 151 individuals m. Clams adjacent to the wet wipe reefs were found to contain synthetic polymers including polypropylene (57%), polyethylene (9%), polyallomer (8%), nylon (8%) and polyester (3%). Some of these polymers may have originated from the wet wipe reefs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envpol.2020.114577DOI Listing

Publication Analysis

Top Keywords

wet wipe
16
wet wipes
12
asian clam
8
clam corbicula
8
corbicula fluminea
8
river thames
8
wipe reefs
8
wet
6
effects wet
4
wipe
4

Similar Publications

Predicting flushed wet wipe emissions into rivers.

Water Res

January 2025

School of Engineering, Cardiff University, Cardiff, CF24 3AA, United Kingdom. Electronic address:

Flushed wet wipes pose a significant pollution risk to river systems at both macro and micro levels. However, the link between their emissions and environmental contamination remains unclear. Here we integrated emissions-based modelling with existing data on wet wipe disposal and microfibre generation to predict the quantity of emissions entering river systems and the transport pathways involved.

View Article and Find Full Text PDF

Skin decontamination with and without water irrigation.

Disaster Med Public Health Prep

October 2024

Arizona Poison and Drug Information Center, College of Pharmacy, University of Arizona, Tucson, AZ, USA.

Objective: Rinsing only with water or washing with soap and water are common methods of skin decontamination for skin contaminated during a chemical hazard release. The null hypothesis was that a 15-minute water irrigation (decontamination method 1) would not be superior to decontamination using a microfiber towel, followed by a wet wipe (Signature Select Softly Flushable Tissue Better Living Brands LLC, Pleasanton, CA), followed by using another microfiber towel (decontamination method 2).

Methods: A simulated contaminant (Magic Fluorescent Glow Paint for Face and Body, iLC Shenzhen Fulimei Technology Co.

View Article and Find Full Text PDF

The skin of newborns is classified as sensitive, with a higher risk of skin barrier disruption and irritation of a diapered area. Despite dermatologist recommendations to use only water and a cloth for cleaning, most of the population still relies on the comforts of modern parenting, which includes intensive daily usage of baby wet wipes. Novel baby formulations are designed following the concept of infant skin health, containing a gentle cleanser, suitable emollient, and buffer system enabling a slightly acidic pH value and they are free of ethyl alcohol.

View Article and Find Full Text PDF

Portable X-ray fluorescence spectrometry: a cost-effective method for analysing trace metals in deposited dust.

Anal Methods

July 2024

School of Natural Sciences, Faculty of Science and Engineering, Macquarie University, Sydney, New South Wales, 2109, Australia.

For projects requiring extensive environmental sampling and rapid decision-making to identify trace metal contamination using dust wipes, the cost and time required for wet chemistry analysis can be prohibitive. Under such circumstances there is a need for a suitable screening method that is cost-effective, efficient, and portable. To address this need, this study investigated the utility of portable X-ray fluorescence (pXRF) for the analysis of trace metals in dust wipes.

View Article and Find Full Text PDF

Chemical resistance testing of plastics: material compatibility of detergent and disinfectant products.

J Hosp Infect

July 2024

Research and Development, GAMA Healthcare Ltd, Halifax, UK. Electronic address:

Background: Surface cleaning and disinfection is a key part of breaking the chain of transmission and reducing the risk of healthcare associated infections. However, if cleaning and disinfectant formulations are incompatible with surface materials, frequent application can cause premature failure of plastics due to environmental stress cracking (ESC). Material compatibility should be considered when selecting cleaning and disinfecting products.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?