AI Article Synopsis

  • Multidrug resistant Gram-negative bacteria, like Pseudomonas putida, are major global health threats, often leading to high mortality in bloodstream infections (BSIs).
  • A case report from Brazil details a non-fatal peripheral line associated BSI in a 72-year-old man caused by P. putida with the blaKPC-2 carbapenemase gene.
  • The study reveals that P. putida can transmit resistance genes, raising concerns about the spread of these resistant pathogens in healthcare and community settings.

Article Abstract

Infections due to multidrug resistant Gram-negative pathogens are of great concern worldwide, as they are frequently associated with high mortality and morbidity rates. The occurrence of Pseudomonas spp. producing Klebsiella pneumoniae carbapenemases (KPCs) imposes a great challenge through treatment course of bloodstream infections (BSIs). Pseudomonas putida has been recognized as an emerging pathogen of healthcare associated infections (HAIs). Therefore, we aimed to report a case of a non-fatal case of peripheral line associated BSI (PLA-BSI) in an immunocompromised host due to P. putida harboring blaKPC-2 gene in Brazil. A P. putida isolate was recovered from a blood culture of a 72-year-old man admitted at a University Hospital, identified by BD Phoenix™ 100 (Becton, Dickinson and Company), causing PLA-BSI. The species identification was confirmed by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) and resistance to carbapenems were confirmed by Epsilometer test (E-test®). Additionally, the presence of important carbapenemases genes (blaKPC, blaNDM, blaOXA-48-like, blaSPM, blaIMP, blaVIM) was investigated by Polymerase Chain Reaction. The bacterial isolate was confirmed as meropenem resistant P. putida harboring blaKPC-2 gene.Thereofre, these fidings suggest that P. putida can work as a reservoir for resistance genes as this bacterium has the ability to disseminate through water-fluids inside hospital and community settings. Moreover, this paper highlights that a frequent and worldwide disseminated mechanism of resistance (blaKPC-2) is currently occurring among uncommon agents of BSI.

Download full-text PDF

Source
http://dx.doi.org/10.3855/jidc.12145DOI Listing

Publication Analysis

Top Keywords

pseudomonas putida
8
putida harboring
8
harboring blakpc-2
8
putida
6
kpc-2 producing
4
producing pseudomonas
4
putida unexpected
4
unexpected pathogen
4
pathogen catheter-associated
4
catheter-associated bloodstream
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!