The Impact of Technology on Prescribing Errors in Pediatric Intensive Care: A Before and After Study.

Appl Clin Inform

Department of Pharmacy, Children's Health Ireland at Crumlin, Dublin, Ireland.

Published: March 2020

Background: Increased use of health information technology (HIT) has been advocated as a medication error reduction strategy. Evidence of its benefits in the pediatric setting remains limited. In 2012, electronic prescribing (ICCA, Philips, United Kingdom) and standard concentration infusions (SCIs)-facilitated by smart-pump technology-were introduced into the pediatric intensive care unit (PICU) of an Irish tertiary-care pediatric hospital.

Objective: The aim of this study is to assess the impact of the new technology on the rate and severity of PICU prescribing errors and identify technology-generated errors.

Methods: A retrospective, before and after study design, was employed. Medication orders were reviewed over 24 weeks distributed across four time periods: preimplementation (Epoch 1); postimplementation of SCIs (Epoch 2); immediate postimplementation of electronic prescribing (Epoch 3); and 1 year postimplementation (Epoch 4). Only orders reviewed by a clinical pharmacist were included. Prespecified definitions, multidisciplinary consensus and validated grading methods were utilized.

Results: A total of 3,356 medication orders for 288 patients were included. Overall error rates were similar in Epoch 1 and 4 (10.2 vs. 9.8%;  = 0.8), but error types differed ( < 0.001). Incomplete and wrong unit errors were eradicated; duplicate orders increased. Dosing errors remained most common. A total of 27% of postimplementation errors were technology-generated. Implementation of SCIs alone was associated with significant reductions in infusion-related prescribing errors (29.0% [Epoch 1] to 14.6% [Epoch 2];  < 0.001). Further reductions (8.4% [Epoch 4]) were identified after implementation of electronically generated infusion orders. Non-infusion error severity was unchanged ( = 0.13); fewer infusion errors reached the patient ( < 0.01). No errors causing harm were identified.

Conclusion: The limitations of electronic prescribing in reducing overall prescribing errors in PICU have been demonstrated. The replacement of weight-based infusions with SCIs was associated with significant reductions in infusion prescribing errors. Technology-generated errors were common, highlighting the need for on-going research on HIT implementation in pediatric settings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7202919PMC
http://dx.doi.org/10.1055/s-0040-1709508DOI Listing

Publication Analysis

Top Keywords

impact technology
8
prescribing errors
8
pediatric intensive
8
intensive care
8
electronic prescribing
8
medication orders
8
orders reviewed
8
epoch postimplementation
8
epoch
5
prescribing
4