The combination of navigation and robotics in spine surgery has the potential to accurately identify and maintain bone entry position and planned trajectory. The goal of this study was to examine the feasibility, accuracy and efficacy of a new robot-guided system for semi-automated, minimally invasive, pedicle screw placement. A custom robotic arm was integrated into a hybrid operating room (OR) equipped with an augmented reality surgical navigation system (ARSN). The robot was mounted on the OR-table and used to assist in placing Jamshidi needles in 113 pedicles in four cadavers. The ARSN system was used for planning screw paths and directing the robot. The robot arm autonomously aligned with the planned screw trajectory, and the surgeon inserted the Jamshidi needle into the pedicle. Accuracy measurements were performed on verification cone beam computed tomographies with the planned paths superimposed. To provide a clinical grading according to the Gertzbein scale, pedicle screw diameters were simulated on the placed Jamshidi needles. A technical accuracy at bone entry point of 0.48 ± 0.44 mm and 0.68 ± 0.58 mm was achieved in the axial and sagittal views, respectively. The corresponding angular errors were 0.94 ± 0.83° and 0.87 ± 0.82°. The accuracy was statistically superior (p < 0.001) to ARSN without robotic assistance. Simulated pedicle screw grading resulted in a clinical accuracy of 100%. This study demonstrates that the use of a semi-automated surgical robot for pedicle screw placement provides an accuracy well above what is clinically acceptable.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7200720 | PMC |
http://dx.doi.org/10.1038/s41598-020-64462-x | DOI Listing |
J Craniomaxillofac Surg
December 2024
Department of Craniomaxillofacial Surgery, University Hospital Schleswig-Holstein Campus Kiel, 24105, Kiel, Germany. Electronic address:
The state-of-the-art approach to open reduction and fixation (ORIF) of zygoma fracture fragments is based on manual skills. Achieving high accuracy can be challenging. Our feasibility study on deceased body donors with artificial zygomatic fractures investigated whether virtual repositioning of the fractures and the use of customised 3D-printed titanium osteosynthesis plates was similar in accuracy to the conventional manual procedure, and whether the method was applicable in a clinical setting.
View Article and Find Full Text PDFMagn Reson Imaging
December 2024
Department of Radiology and Diagnostic Imaging, Nicolaus Copernicus University, Collegium Medicum, Bydgoszcz, Poland.
Background: Brain tumors exhibit diverse genetic landscapes and hemodynamic properties, influencing diagnosis and treatment outcomes.
Purpose: To explore the relationship between MRI perfusion metrics (rCBV, rCBF), genetic markers, and contrast enhancement patterns in gliomas, aiming to enhance diagnostic accuracy and inform personalized therapeutic strategies. Additionally, other radiological features, such as the T2/FLAIR mismatch sign, are evaluated for their predictive utility in IDH mutations.
PLoS One
December 2024
Faculty of Geosciences and Engineering, Southwest Jiaotong University, Chengdu, China.
The existing landslide monitoring methods are unable to accurately reflect the true deformation of the landslide body, and the use of a single SAR satellite, affected by its revisit cycle, still suffers from the limitation of insufficient temporal resolution for landslide monitoring. Therefore, this paper proposes a method for the dynamic reconstruction and evolutionary characteristic analysis of the Gaojiawan landslide's along-slope deformation based on ascending and descending orbit time-series InSAR observations using Kalman filtering. Initially, the method employs a gridded selection approach during the InSAR time-series processing, filtering coherent points based on the standard deviation of residual phases, thereby ensuring the density and quality of the extracted coherent points.
View Article and Find Full Text PDFPhys Eng Sci Med
December 2024
Department of Medical Imaging and Nuclear Medicine, Gosford Hospital, Building K3, Gosford, NSW, Australia.
Quantitative accuracy and constancy of Siemens xSPECT Bone quantitative reconstruction algorithm (xBone) can be monitored using activity-filled hollow spheres, which could be 3D printed (3DP) to increase accessibility to phantoms. One concern is that 3D prints can have air gaps in the walls which may pose issues for attenuation correction and xBone tissue zone mapping. This study assessed the feasibility of using 3DP spheres (3DP-S) with materials PLA, PETG and Resin as substitutes for commercial hollow spheres (C-S).
View Article and Find Full Text PDFSci Rep
December 2024
Hunan University of Chinese Medicine, Changsha, China.
Stroke has become the leading cause of disability in adults worldwide. Early precise rehabilitation intervention is crucial for the recovery of stroke patients, with the key lying in accurately identifying patients' physical characteristics during the rehabilitation phase. Compared to diagnostic techniques such as medical neuroimaging, traditional Chinese medicine(TCM) tongue diagnosis offers good accessibility and ease of application.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!