A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiation dose reduction using novel size 1 and size 0 rectangular collimators in pediatric dental imaging. | LitMetric

Objectives: Commercial intraoral rectangular collimators are available for collimating to size 2 image receptor. The benefits of reducing the x-ray beam to match the area of the image detector in adult intraoral radiography are endorsed internationally. However, in pediatric dentistry the image receptor can be further decreased to size 1 and 0.

Method And Materials: For this study size 1 and 0 rectangular collimators were fabricated using 1.65-mm lead sheets (Rotometals). The custom-fabricated collimators were fixed to the plastic body of a Rinn (Dentsply) Universal Collimator attachment. Aperture sizes were extrapolated based on the active imaging area of size 1 and 0 digital image receptors. A dose area product (DAP) measuring device was used to determine the change in radiation absorbed dose as a function of the imaging field of view.

Results: DAP measurements were evaluated in the 31.7 cm2 conventional round collimation, Rinn 12.0 cm2 Universal rectangular collimator, and in the manufactured size 1 (8.25 cm2) and size 0 (5.72 cm2) rectangular collimators. The size 1 collimator had a 32% DAP reduction from the size 2, and a 53% reduction for the size 0.

Conclusion: Size 1 and size 0 rectangular collimators can be independently manufactured and utilized in pediatric dentistry. This study suggests that a considerable radiation dose reduction is possible in pediatric intraoral imaging when using the size 1 and 0 matched collimation. Since the pediatric population is vulnerable to radiation exposure, any measurable reduction has a potential for long-term health benefits and is therefore clinically significant.

Download full-text PDF

Source
http://dx.doi.org/10.3290/j.qi.a44495DOI Listing

Publication Analysis

Top Keywords

rectangular collimators
20
size
14
size rectangular
12
radiation dose
8
dose reduction
8
size size
8
image receptor
8
pediatric dentistry
8
reduction size
8
rectangular
6