Corneal collagen cross-linking (CXL) is a procedure that aims to halt the progression of corneal ectasia in keratoconic eyes. It is achieved by inducing cross-links in the corneal stroma and extracellular matrix by exposing it to ultraviolet-A (370 nm) irradiation while it is filled with photosensitizer (riboflavin). According to the conventional protocol, the recommended de-epithelialized corneal thickness should be higher than 400 μm in order to avoid radiation damage to the corneal endothelium. However, in progressive keratoconus, corneal thickness is often close to or lower than this threshold of 400 μm, which limits the application of cross-linking for these patients. The present article reviews the different protocols of cross-linking for thin corneas, their advantages and disadvantages. At present, clinical research on modified cross-linking protocols is still limited due to the methodology and a low number of patients involved. Thus, comparative randomized controlled studies with long-term follow-up are necessary to confirm the safety and effectiveness of several CXL protocols and identify the most efficient one.

Download full-text PDF

Source
http://dx.doi.org/10.17116/oftalma202013602199DOI Listing

Publication Analysis

Top Keywords

corneal thickness
8
400 μm
8
corneal
6
[ultraviolet crosslinking
4
crosslinking treatment
4
treatment keratoconus
4
keratoconus patients
4
patients thin
4
thin corneas]
4
corneas] corneal
4

Similar Publications

This prospective cohort study is aimed to investigate circadian variations in corneal parameters, focusing on sleep-deprived subjects. Sixty-four healthy individuals (age range: 21-76 years) actively participated in this study, undergoing examinations at least five times within a 24-hour timeframe. The analysis encompassed keratometric parameters of the cornea's front (F) and back (B) surfaces, refractive power in flattest and steepest axes (K1, K2), astigmatism (Astig) and its axis (Axis), aspheric coefficient (Asph), corneal pachymetry values of thinnest corneal thickness (Pachy Min) and corneal thickness in the center of the pupil (Pachy Pupil), volume relative to the 3 and 10 mm corneal diagonal (Vol D3, Vol D10) and surface variance index (ISV).

View Article and Find Full Text PDF

To observe the characteristics of ocular biological parameters in children with transfusion-dependent β-thalassemia (TDT) and the effect of iron chelator treatment on them. This was a cross-sectional study. Thirty-two children with TDT (TDT group) and 64 healthy children (control group) who were treated in the Affiliated Hospital of Guangdong Medical University from October 2022 to June 2023 were included.

View Article and Find Full Text PDF

Purpose: Osteogenesis imperfecta (OI) is a rare hereditary disorder of the connective tissue. Despite recent attention to corneal abnormalities in OI, understanding remains limited. This study aimed to comprehensively evaluate corneal changes in a large sample of OI patients compared to controls using in vivo confocal microscopy (IVCM).

View Article and Find Full Text PDF

Background: To evaluate the ocular biometry agreement and prediction of postoperative refractive outcomes obtained using two swept-source optical coherence tomography (SS-OCT) biometers: Anterion (Heidelberg Engineering, Heidelberg, Germany) and Argos (Alcon, Fort Worth, TX, USA).

Methods: Ambispective analysis was conducted on 105 eyes at the Samsung Medical Center, Seoul, Republic of Korea, between June 2021 and March 2022. Biometric values were assessed using both devices before cataract surgery.

View Article and Find Full Text PDF

Fuchs' endothelial corneal dystrophy (FECD) is a common sight-threatening condition characterised by pathological changes in the posterior cornea. Here we report observations by light, transmission and volume scanning electron microscopy on changes in the endothelium and matrix associated with the characteristic deformations of Descemet's membrane, termed guttae. Specimens were archived full-thickness human corneal tissue, removed during graft surgery, that had been fixed, stained and embedded by conventional processing methods for examination by transmission electron microscopy more than 40-years previously.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!