We quantified intra-fractional dose variation and organ movement during CT-based 3D-image guided brachytherapy (3D-IGBT) in cervical cancer patients. Fifteen patients who underwent CT-based 3D-IGBT were studied. For all patients, pre-delivery CT for treatment planning after applicator insertion and post-delivery CT after dose delivery without changing the applicator position were acquired. Pre- and post-delivery CT were rigidly fused by matching the inserted applicator and planned dose on pre-delivery CT (pre-delivery dose) was mapped on post-delivery CT (post-delivery dose). D2, D1, and D0.1 cm of the rectum and bladder were compared between pre- and post-delivery doses with contours on each CT image. Organ movement and deformation was evaluated using deformation vector fields calculated by deformable image registration between pre- and post-delivery CT. We also evaluated dose variation and DVF between with and without a catheter to control filling. Differences in all DVH parameters were <±3% in physical dose and ± 5% in EQD2. However, a > 15% dose difference was found in 13.8% of the fractions in rectum D2 cm and in 11.1% of those in bladder D2 cm. The mean value of DVF for bladder was larger than that of rectum, especially for the superior-inferior (S-I) direction. Insertion catheters in bladder reduced mean dose and DVF variation compared with that of without catheters. In fraction groups with large dose increasing, DVF in the S-I direction was significantly larger than that of other fraction groups. Our results indicated that preparation is needed to reduce changes in the S-I direction affect dose variation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2020.04.009DOI Listing

Publication Analysis

Top Keywords

dose variation
12
pre- post-delivery
12
s-i direction
12
dose
10
guided brachytherapy
8
cervical cancer
8
cancer patients
8
organ movement
8
post-delivery dose
8
fraction groups
8

Similar Publications

Objectives: Due to the increasing use of cone-beam computed tomography (CBCT) in dentistry and considering the effects of radiation on radiosensitive organs, the aim of this study was to investigate the effect of shielding on absorbed dose of eyes, thyroid and breasts in scans conducted with different parameters using two different fields of view (FOV).

Methods: Dose measurements were calculated on a tissue-equivalent female phantom by repeating each scanning parameter three times and placing at least two thermoluminescent dosimeters (TLD) on each organ, with the averages then taken. The same CBCT scans were performed in two different FOV with shielding including thyroid collar, radiation safety glasses and lead apron and without shielding.

View Article and Find Full Text PDF

AI-based automatic patient positioning in a digital-BGO PET/CT scanner: efficacy and impact.

EJNMMI Phys

January 2025

Department of Nuclear Medicine, Rambam Health Care Campus, P.O.B. 9602, 3109601, Haifa, Israel.

Background: A recently released digital solid-state positron emission tomography/x-ray CT (PET/CT) scanner with bismuth germanate (BGO) scintillators provides an artificial intelligence (AI) based system for automatic patient positioning. The efficacy of this digital-BGO system in patient placement at the isocenter and its impact on image quality and radiation exposure was evaluated.

Method: The digital-BGO PET/CT with AI-based auto-positioning was compared (χ, Mann-Whitney tests) to a solid-state lutetium-yttrium oxyorthosilicate (digital-LYSO) PET/CT with manual patient positioning (n = 432 and 343 studies each, respectively), with results split into groups before and after the date of a recalibration of the digital-BGO auto-positioning camera.

View Article and Find Full Text PDF

Effect of a calcium-channel blocker and β-blocker combination on reading-to-reading blood pressure variability: a randomized crossover trial.

Blood Press Monit

November 2024

Department of Cardiovascular Medicine, Centre for Epidemiological Studies and Clinical Trials, State Key Laboratory of Medical Genomics, Shanghai Key Laboratory of Hypertension, Shanghai Institute of Hypertension, National Research Centre for Translational Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Objective: The objective of this study was to investigate the efficacy of the nitrendipine/atenolol combination in comparison with standard-dose nitrendipine or atenolol monotherapy in reducing blood pressure (BP) and blood pressure variability (BPV) as assessed by ambulatory BP monitoring.

Methods: In a randomized, crossover trial, 32 patients (30-65 years) with grade 1 hypertension and elevated daytime reading-to-reading BPV were randomly assigned to receive either the nitrendipine/atenolol combination (10/20 mg) or standard-dose nitrendipine (10 mg) or atenolol (25 mg) monotherapy for 6 weeks, followed by a crossover to another treatment for 6 weeks.

Results: The final analysis included 31 patients (mean [±SD] age, 49.

View Article and Find Full Text PDF

Objectives: This study evaluates the performance of a clinical dual-source photon-counting computed tomography (PCCT) system in quantifying iodine within calcified vessels, using 3D- printed phantoms with vascular-like structures lined with calcium.

Methods: Parameters assessed include lumen diameters (4, 6, 8, 10, and 12 mm), phantom sizes (S: 20×20 cm, M: 25×25 cm, L: 30×40 cm, XL: 40×50 cm, representing the 99th percentile of US patient sizes), and iodine concentrations (2, 5, and 10 mg/mL). Scans were performed at radiation dose levels of 5, 10, 15, and 20 mGy to systematically evaluate iodine quantification accuracy and spectral imaging performance.

View Article and Find Full Text PDF

Dosage-sensitive transcription factors (TFs) underlie altered gene regulation in human developmental disorders, and cell-type specific gene regulation is linked to the reorganization of 3D chromatin during cellular differentiation. Here, we show dose-dependent regulation of chromatin organization by the congenital heart disease (CHD)- linked, lineage-restricted TF TBX5 in human cardiomyocyte differentiation. Genome organization, including compartments, topologically associated domains, and chromatin loops, are sensitive to reduced dosage in a human model of CHD, with variations in response across individual cells.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!