A simple electrochemical approach to fabricate functionalized MWCNT-nanogold decorated PEDOT nanohybrid for simultaneous quantification of uric acid, xanthine and hypoxanthine.

Anal Chim Acta

Department of Polymer Science and Technology, University of Calcutta, 92 APC Road, Kolkata, 700009, India; Calcutta Institute of Technology, Banitabla, Uluberia, Howrah, 711316, India. Electronic address:

Published: June 2020

Medical diagnostics and detection of food spoilage require estimation of hypoxanthine (HX), xanthine (XN), and uric acid (UA). A selective sensing platform has been proposed for simultaneous detection of all these species. Functionalized multi-walled carbon nanotube (fMWCNT) stabilized nanogold decorated PEDOT:TOS polymeric nanocomposite (Au-PEDOT-fMWCNT) was synthesized through rapid one-step electropolymerization to enhance conductivity and active surface area by several folds. Electrochemical activities of the proposed sensing platform were analyzed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS). Analyses through SEM, FESEM and TEM were performed to explore the surface morphology and elemental analysis of the polymeric nanohybrid was investigated by XPS, Raman, FTIR, XRD spectroscopy. Electro-catalysis of UA, XN and HX occurred at low oxidation potentials i.e. 0.082, 0.463 and 0.808 V, respectively in the optimized conditions. The uniquely designed simple, interference free Au-PEDOT-fMWCNT/GCE sensor exhibited high selectivity, good reproducibility, reusability (∼180 times) and stability (∼3 month) with excellent sensitivity of 1.73, 14.31 and 3.82 μA μM cm for UA, XN and HX, respectively. The sensor exhibited linear ranges of detection as 0.1-800, 0.05-175 and 0.1-150 μM with detection limits of 199.3, 24.1 and 90.5 nM for quantification of UA, XN and HX respectively. The performance of the proposed sensor was validated by addition of UA, XN and HX in human serum, urine and fish samples by comparing to those using HPLC. The results indicated good applicability of the proposed sensor for simultaneous detection of UA, XN, HX in real biological fluids.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2020.03.060DOI Listing

Publication Analysis

Top Keywords

uric acid
8
sensing platform
8
simultaneous detection
8
sensor exhibited
8
proposed sensor
8
detection
5
simple electrochemical
4
electrochemical approach
4
approach fabricate
4
fabricate functionalized
4

Similar Publications

: Increased dietary antioxidant capacity is a good means of lowering oxidative stress and cardiovascular risk. Established antioxidant capacity doses should be tested using dietary intervention. : We analysed the influence of a high-antioxidant-capacity diet on oxidative stress (OS) and inflammatory and lipid profile in CVD (cardiovascular disease) subjects with initially low (LowA) and high (HighA) antioxidant capacity markers.

View Article and Find Full Text PDF

Deoxynivalenol (DON) and toxins (ATs) are two common types of mycotoxins in food. Although they are physiologically toxic to animals and various cell lines, data related to the exposure risks and health effects in the human population were still limited, especially for ATs. In this study, we combined food consumption data and human biomonitoring data of 200 pregnant volunteers from different districts of Shanghai to assess the exposure to DON and ATs.

View Article and Find Full Text PDF

Background: Metabolic disorders and chronic liver disease (CLD) play crucial roles in the development and progression of liver cancer (LC). Since the ethnic minority population increasingly suffers from CLD and LC, it is vital to understand the biosocial factors contributing to CLD and LC. The 'All of Us' database, with significant participation from minority populations, provides a valuable tool for studies in different racial/ethnic groups.

View Article and Find Full Text PDF

Objectives: Nephrolithiasis, with a prevalence of 9% and increasing worldwide, has a recurrence rate close to 50%. Urinary stones significantly impact quality of life and impose substantial economic burdens on patients and healthcare systems. Systemic inflammation is postulated as a risk factor for urinary stones.

View Article and Find Full Text PDF

This study aimed to explore the relationship between biochemical profiles and the risk of age-related macular degeneration (AMD) through a cross-sectional observational analysis. We examined data of U. S.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!