Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Malpositioning of the acetabular cup during total hip arthroplasty (THA) increases the risk of certain complications and shortens the lifespan of the prosthetic joint. Therefore, the accurate placement of the acetabular component during a THA is a necessary contributing factor to its successful outcome. The different methods of intraoperative estimation of acetabular component positioning are quite varied and sometimes may be inaccurate. The purpose of this study was to assess the accuracy of intraoperative acetabular component orientation with the assistance of three-dimensional (3D), patient-specific guidance alone.
Materials And Methods: At a single institution, a total of 56 patients were prospectively enrolled into this study. Acetabular cup positioning was achieved with a described method using a laser beam technique minus the placement of pelvic pins. Comparison was made between the planned, preoperative inclination and version angles with the achieved postoperative inclination and version of the acetabular component in all THAs performed. The accuracy of placement of the acetabular cup was assessed using postoperative computed tomography (CT) scans. Evaluation was performed by an independent orthopaedic surgeon.
Results: Fifty-eight hips were included in the present study. The mean absolute deviation from the preoperative planned inclination and anteversion was 4.0° (0.1° to 14.6°; p<0.05) and 4.4° (0.2° to 12.2°; p<0.05) respectively. The planned inclination and anteversion were achieved within a +/- 10° target in 98% of the cases respectively.
Conclusion: Accuracy of acetabular cup orientation in total hip arthroplasty can be achieved to a high degree with 3D patient-specific guidance alone. This eliminates the pins in the pelvis and has the potential to reduce costs and patient trauma without impacting accuracy.