A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simulations of Benzene and Hydrogen-Sulfide Gas Detector Based on Single-Walled Carbon Nanotube over Intrinsic 4H-SiC Substrate. | LitMetric

Carbon nanotubes (CNTs)-based sensors have gained significant importance due to their tremendous electrical and physical attributes. CNT-based gas sensors have high sensitivity, stability, and fast response time compared to that of solid-state sensors. On exposure to a large variety of organic and inorganic compounds, the conductivity of CNT changes. This change in electrical conductivity is being used as a detection signal to detect different target molecules. Hydrogen-sulfide and benzene are hazardous gases that can cause serious health issues in humans. Therefore, it is mandatory to detect their presence in industrial and household environments. In this article, we simulated CNT-based benzene and hydrogen-sulfide sensor with a nanoscale semiconductor device simulator-Quantumwise Atomistix Toolkit (ATK). The change in the device density of states, electric current, and photocurrent in the presence of target molecules have been calculated. The change in photocurrent in the presence of target molecules has been proposed as a novel detection mechanism to improve the sensor selectivity and accuracy. This change in photocurrent as well as electric current in the presence of target molecules can be used simultaneously as detection signals. Our intension in the future is to physically fabricate this simulated device and use photocurrent as well as electric current as detection mechanisms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7281424PMC
http://dx.doi.org/10.3390/mi11050453DOI Listing

Publication Analysis

Top Keywords

target molecules
16
electric current
12
presence target
12
benzene hydrogen-sulfide
8
photocurrent presence
8
change photocurrent
8
photocurrent well
8
well electric
8
simulations benzene
4
hydrogen-sulfide gas
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!