Fabry-Perot-based ultrasound sensors at fiber tips have performed high sensitivity and immunity of electromagnetic interference with a relatively compact size. Nevertheless, the reverberation at fiber tips causes a strong noise that degrades the sensing capability. Here we propose a fiber optical-based ultrasound sensor with three design approaches to reduce the reverberation, including designs with an eccentric core, absorptive shield, and arc edge. The effect was experimentally validated with a photoacoustic signal excitation. Compared with bare single-mode fibers in simulation, the low-reverberation design increased the signal-to-noise ratio by 32.1 dB with identical excitation. The experimental results demonstrated the "clean" response with almost invisible reverberations, which was validated by a commercial hydrophone. This research solved the reverberation problems and provided a low-noise design for fiber optic ultrasound sensing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.389708 | DOI Listing |
Small Struct
November 2024
Department of Surgery-Transplant and Mary & Dick Holland Regenerative Medicine Program, University of Nebraska Medical Center, Omaha, NE, 68198, USA.
Taking inspiration from diverse interlocking and adhesion structures found in nature, a biaxially interlocking interface is developed in this work. This interface is formed by interconnecting two electrostatically flocked substrates and its mechanical strength is enhanced through the incorporation of enoki mushroom-shaped microfibers and deposited extracellular matrix (ECM). Tips of flocked straight fibers can be transformed into mushroom shapes through thermal treatment.
View Article and Find Full Text PDFJ Cell Sci
December 2024
Institute of Sports Medicine Copenhagen, Department of Orthopaedic Surgery, Copenhagen University Hospital - Bispebjerg and Frederiksberg, Copenhagen, Denmark.
The myotendinous junction (MTJ) is a weak link in the musculoskeletal system. Here, we isolated the tips of single myofibres from healthy human hamstring muscles for confocal microscopy (n=6) and RNAscope in situ hybridisation (n=6) to gain insight into the profiles of cells and myonuclei in this region, in a fibre type manner. A marked presence of mononuclear cells was observed coating the myofibre tips (confirmed by serial block face scanning electron microscopy and cryosection immunofluorescence), with higher numbers for type I (median 29; range 16-63) than type II (16; 9-23) myofibres (p<0.
View Article and Find Full Text PDFSensors (Basel)
November 2024
Institute of Concrete Structures, TUD Dresden University of Technology, 01062 Dresden, Germany.
Because of their high spatial resolution over extended lengths, distributed fiber optic sensors (DFOS) enable us to monitor a wide range of structural effects and offer great potential for diverse structural health monitoring (SHM) applications. However, even under controlled conditions, the useful signal in distributed strain sensing (DSS) data can be concealed by different types of measurement principle-related disturbances: strain reading anomalies (SRAs), dropouts, and noise. These disturbances can render the extraction of information for SHM difficult or even impossible.
View Article and Find Full Text PDFPlants (Basel)
November 2024
Sam Farr United States Crop Improvement and Protection Research Center, Agricultural Research Service, U.S. Department of Agriculture, Salinas, CA 93905, USA.
Lettuce ( L.) is a popular leafy vegetable valued for its dietary fiber, antioxidants, and beneficial vitamins. This study presents a comprehensive spatio-temporal analysis of the lettuce metabolome, revealing complex dynamics in metabolite accumulation influenced by plant age, leaf position, proximodistal distribution within a leaf, and head closure.
View Article and Find Full Text PDFJBJS Essent Surg Tech
December 2024
Department of Orthopedics, OhioHealth Health System, Columbus, Ohio.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!