Objective:  The aim of this study was to describe the use of patient-specific three-dimensional (3D)-printed osteotomy guides, repositioning guides and custom-printed titanium plates for acute correction of antebrachial limb deformities in four dogs.

Methods:  Retrospective review of antebrachial limb deformities in small breed chondrodystrophic dogs that were surgically corrected using a closing wedge ostectomy of the radius at a predetermined site using patient-specific osteotomy guides. Reduction was achieved without the need for intraoperative measurements using patient-specific 3D-printed repositioning guides secured and manipulated using temporary Kirschner wire fixation. The ostectomy of the radius was stabilized with a patient-specific 3D-printed titanium plate.

Results:  All limbs were corrected to within 3.5 degrees (standard deviation [SD]: 1 degree) and 7.5 degrees (SD: 3 degrees) of the pre-planned deformity correction in the frontal and sagittal planes, respectively. No complications were encountered. Owners completed a canine orthopaedic index survey at a median postoperative follow-up time of 19 months. Surgery eliminated the main presenting complaint of buckling over of the manus in all cases.

Clinical Significance:  The 3D-printed osteotomy repositioning guides and titanium plates facilitated accurate acute correction of antebrachial deformities in this case series. The methodology described simplifies intraoperative surgical decision-making on limb position with good clinical outcomes seen in a small number of clinical cases.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1709702DOI Listing

Publication Analysis

Top Keywords

repositioning guides
16
osteotomy guides
12
titanium plates
12
acute correction
12
correction antebrachial
12
antebrachial limb
12
limb deformities
12
patient-specific osteotomy
8
guides repositioning
8
guides titanium
8

Similar Publications

Background: In persistent atrial fibrillation (AF), localized extra-pulmonary vein sources may contribute to arrhythmia recurrences after pulmonary vein isolation. This in-silico study proposes a high-density sequential mapping strategy to localize such sources.

Method: Catheter repositioning was guided by repetitive conduction patterns, moving against the prevailing conduction direction (upstream) toward the sources.

View Article and Find Full Text PDF

Facial feminization surgery (FFS) is critical to gender-affirming surgery, consisting of craniomaxillofacial procedures to align facial features with a patient's gender identity. Central to FFS is genioplasty, which reshapes or repositions the chin; however, limited research exists on genioplasty in FFS. This review and cohort analysis aim to evaluate current practices and outcomes for individuals undergoing FFS with genioplasty.

View Article and Find Full Text PDF

Intrafraction Patient Positional Uncertainty in Lung Stereotactic Ablative Radiotherapy with Abdominal Compression.

Pract Radiat Oncol

December 2024

Department of Radiation Oncology, Willis Knighton Cancer Center, 2600 Kings Highway, Shreveport, Louisiana, USA 71103 &, Department of Clinical Research, University of Jamestown, Fargo, ND, USA. Electronic address:

Purpose: Motion management presents a significant challenge in thoracic stereotactic ablative radiotherapy (SABR). Currently, a 5.0 mm standard planning target volume (PTV) margin is widely used to ensure adequate dose to the tumor.

View Article and Find Full Text PDF

. Adult medulloblastoma (AMB) patients should receive postoperative craniospinal irradiation (CSI) as a standard treatment. Volumetric intensity-modulated arc therapy (VMAT) is a promising method for CSI.

View Article and Find Full Text PDF
Article Synopsis
  • A new device for guiding the nasobiliary catheter via an adjustable snare and a handle has been developed to enhance endoscopic nasobiliary drainage procedures.
  • The study involved patients at Zhongnan Hospital, comparing the new technique's effectiveness against the traditional guidewire method in terms of success rate, procedure time, and patient comfort.
  • Results showed the new technique significantly increased successful catheter repositioning and reduced procedure time and patient discomfort compared to the conventional approach.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!