Objectives: To compare the efficacy and safety of diode laser and electrocautery techniques for inflammatory fibrous hyperplasia (IFH) removal.

Materials And Methods: In this randomized double-blind clinical trial, 40 individuals were randomly allocated to two groups: group 1 (G1) consisted of 20 individuals assigned to treatment with diode laser and group 2 (G2) consisted of 20 individuals assigned to treatment with electrocautery. The following transoperative parameters were evaluated: bleeding, temperature, and surgical technique parameters (energy deposited on tissue, flow rate, and time of incision). The postoperative parameters evaluated were as follows: pain, functional alterations (chewing, speaking), analgesic medication intake, swelling, healing of the wound area, and patient satisfaction.

Results: Among the 40 individuals included in the study, four (two in G1 and two in G2) did not complete the entire follow-up. Therefore, 36 individuals (18 in G1 and 18 in G2) participated. Participants in G1 and in G2 had similar demographic characteristics. No difference regarding the trans- or postoperative parameters evaluated was observed between G1 and G2 (p > 0.05). Also, no difference regarding the time for healing was observed between groups.

Conclusions: Diode laser seems to be as effective and safe as electrocautery when applied under similar conditions for IFH removal.

Clinical Relevance: IFH corresponds to 65% of the lesions observed in denture wearers. This study shows that under similar conditions diode laser is as effective and safe as electrocautery for removal of IFH.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-020-03296-3DOI Listing

Publication Analysis

Top Keywords

diode laser
20
parameters evaluated
12
inflammatory fibrous
8
fibrous hyperplasia
8
randomized double-blind
8
double-blind clinical
8
clinical trial
8
group consisted
8
consisted individuals
8
individuals assigned
8

Similar Publications

Objective:  This study compares the color change of non-vital anterior teeth after laser-activated bleaching and conventional walking bleaching technique.

Materials And Methods:  Sixty extracted teeth were endodontically treated, stained in a black tea solution, and the baseline shade was measured using a spectrophotometer (Easyshade, VITA). Bleaching was done using either: internal bleaching with 35% HO (Opalescence Endo) and then tooth sealed for 5 days (Gr1), 35% HO (JW Next) for 7 minutes (Gr2), internal and external bleaching for 7 minutes (Gr3), diode laser-activated internal bleaching for 30 seconds (940 nm, continuous wave, 2 W, noncontact mode, 300 um, non-initiated tip), wait for 7 minutes, second laser application for 30 seconds, tooth sealed for 5 days (Gr4), diode laser-activated internal bleaching for 24 hours (Gr5), or diode laser-activated internal and external bleaching for 24 hours (Gr6) ( = 10).

View Article and Find Full Text PDF

Aim: The aim of this study was to investigate and compare the antimicrobial effects of an 810-nanometer diode laser, utilizing or not utilizing toluidine blue as a photosensitizer, in the management of peri-implant mucositis.

Settings And Design: The present study was carried out in 30 implant sites in 15 patients with peri-implant mucositis with a specific inclusion and exclusion criteria. 15 sites were treated utilizing a diode laser (control group) and 15 with photodynamic therapy (test group) in a split-mouth format.

View Article and Find Full Text PDF

Introduction: Laser ablation using a 980-nm wavelength diode laser, which is a new-generation laser, for recurrent bladder cancer is known to have a lower incidence of complications and recurrence than conventional transurethral resection of bladder tumor surgery. This is the first study to report the use of 980-nm diode laser ablation for recurrent non-muscle-invasive bladder cancer in Japan.

Case Presentation: A 73-year-old man underwent transurethral laser ablation for the treatment of recurrent non-muscle-invasive bladder cancer.

View Article and Find Full Text PDF

Background: The use of non-ablative fractionated lasers for skin rejuvenation has been proven to be effective in improving skin texture, and has become popular due to minimal wounding, significantly shorter recovery times and decreased adverse effects.

Objective: To retrospectively analyze improvement in skin texture in healthy women aged over 18 years with Fitzpatrick skin type II-IV.

Methods: Participants received 3 facial and/or neck treatments with the 1570-nm fractional scanning diode laser at one-month intervals.

View Article and Find Full Text PDF

A novel, compact, and automated laser ablation dielectric barrier discharge thin layer chromatography-mass spectrometry (LA-DBD-TLC-MS) device was developed for the rapid detection of biogenic amines (BAs) in fishery products. This plug-and-play system integrates thermal desorption via diode laser, DBD plasma ionization, and tandem MS detection, with key operational parameters optimized through experimental and computational methods. Utilizing nanoscale carbon black as a matrix, the device achieved a detection limit of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!