A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation. | LitMetric

Introduction: Carbon-fiber-reinforced polyetheretherketone (CFR) composite plates have a more favorable stress modulus than stainless steel (SS) plates that may confer an advantage to bridge plating. The purpose of this study was to compare callus formation after CFR and SS plating of distal femur fractures.

Methods: A retrospective review identified distal femoral fractures treated with CFR (n = 10) and SS (n = 21) plate fixation. Callus formation was measured using the modified Radiographic Union Score for Tibia (mRUST) at 3- and 6-month follow-up by three orthopedic trauma surgeons. Loss of alignment, implant failure, and revision surgeries were reviewed.

Results: At 3 months, the mRUST in the CFR and SS groups was 9.0 (range, 6.3-12.3) and 6.9 (range, 4.3-11.7), respectively (p = 0.01). At 6 months, the mRUST in the CFR and SS groups was 11.4 (range, 7.7-16.0) and 10.5 (range, 6.0-15.7), respectively (p = 0.3). CFR and SS groups had a loss of fracture alignment in 1 (10%) and 1 (5%) patient, respectively (p = 0.5), and an unplanned revision surgery in 0 (0%) and 3 (15%) patients, respectively (p = 0.2). All three revisions surgeries in the SS group were for nonunion repair.

Conclusions: Treatment of distal femur fractures with CFR versus SS plating resulted in greater callus formation at 3 months. At 6 months, there was no difference in callus formation between groups. A larger series of patients is necessary to determine if the observed early increased callus formation confers a benefit to clinical outcomes.

Level Of Evidence: Therapeutic level III.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-020-02681-8DOI Listing

Publication Analysis

Top Keywords

callus formation
24
distal femur
12
cfr groups
12
femur fractures
8
stainless steel
8
plate fixation
8
mrust cfr
8
cfr
7
formation
6
callus
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!